Site Background Information: Fisco Warehouse <br /> Page S of 5 <br /> influence is approximately 30 feet; at 10.0 inches of water the radius of influence is <br />' approximately 13 feet.Based on the United States Environmental Protection Agency(EPA)- <br /> prepared document,How to Evaluate Alternative Cleanup Technologies For UST sites, the <br /> radius of influence is considered to be the distance from the extraction well at which a <br />' vacuum of at least 0.1 inches of water is observed.Based upon an effective vacuum potential <br /> of 0.1 inches of water, the calculated effective radius of influence at the site will be <br /> approximately 47 feet. <br />' On 31 July 2003,ground water monitoring well MW-8 was installed at the site to a depth of 95 feet <br /> bsg. Seven soil samples were submitted for laboratory analysis from pilot boring MW-8. THP-g, <br />' TPH-d, BTEX, and the five fuel additives were not detected at or above laboratory reporting limits <br /> in the soil samples submitted,nor were they detected at or above reporting limits in the first ground <br /> water sample collected from MW-8 in August 2003. <br /> I <br /> 1 <br /> 1 <br /> 1 <br />' Advanced GeoEnvironmental,Inc <br /> 1 <br />