Laserfiche WebLink
' 1 Autilus 61KUIY-0K1t tKtA1 <br /> Glossary of Qualifier Codes: <br /> Q1 - Temperatures out of recommended range; corrective action taken and recorded in Test <br /> Temperature Correction Log <br /> Q2- Temperatures out of recommended range; no action taken,test terminated same day <br /> Q3- Sample aerated prior to initiation or renewal due to dissolved oxygen (D.O.) levels below 6.0 <br /> mg/L <br /> Q4- Test aerated; D.O. levels dropped below 4.0 mg/L <br /> Q5- Test initiated with aeration due to an anticipated drop in D.O. <br /> Q6- Airline obstructed or fell out of replicate and replaced; drop in D.O. occurred <br /> Q7- Salinity out of recommended range <br /> Q8- Spilled test chamber/Unable to recover test organism(s) <br /> Q9- Inadequate sample volume remaining, 50% renewal performed <br /> Q10- Inadequate sample volume remaining, no renewal performed <br /> Q11 - Sample out of holding time; refer to QA section of report <br /> Q12- Replicate(s) not initiated; excluded from data analysis <br /> Q13- Survival counts not recorded due to poor visibility or heavy debris <br /> Q14- D.O. percent saturation was checked and was:5 110% <br /> Q15- Did not meet minimum test acceptability criteria. Refer to QA section of report. <br /> Q16- Percent minimum significant difference (PMSD) was below the lower bound limit for acceptability. <br /> This indicates that statistics may be over-sensitive in detecting a difference from the control due <br /> to low variability in the data set. <br /> Q17- Percent minimum significant difference(PMSD)was above the upper bound limit for acceptability. <br /> This indicates that statistics may be under-sensitive in detecting a difference from the control due <br /> to high variability in the data set. <br /> Q18- Incorrect Entry <br /> Q19- Illegible Entry <br /> Q20- Miscalculation <br /> Q21 - Other(provide reason in comments section) <br /> Q22- Greater than 10% moitality observed upon receipt and/or in holding prior to test initiation. <br /> Organisms acclimated to test conditions at Nautilus and ultimately deemed fit to use for testing. <br /> Q23- Test organisms received at a temperature greater than 3°C outside the recommended test <br /> temperature range. However, due to age-specific protocol requirements and/or sample holding <br /> time constraints, the organisms were used to initiate tests upon the day of arrival. Organisms <br /> were acclimated to the appropriate test conditions upon receipt and prior to test initiation. <br /> Q24- Test organisms received at salinity greater than 3 ppt outside of the recommended test salinity <br /> range. However, due to age-specific protocol requirements and/or sample holding time <br /> constraints, the organisms were used to initiate tests upon the day of arrival. Organisms were <br /> acclimated to the appropriate test conditions upon receipt and prior to test initiation. <br /> Updated: 6/30/15 <br /> 8of9 <br />