Laserfiche WebLink
Environmental Health Department <br /> Small Quantity Hazardous Waste Generator Inspection Report <br /> Facility Name: Facility Address: Date: <br /> QU ' TEROS AUTO REPAIR 1555 REPORT AVE, STOCKTON ":oer 18, 2019 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS 1,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 101 CCR 66262.12 Managed a hazardous waste without an identification number. <br /> OBSERVATION:This business does not have a hazardous waste ID number in the California Department of Toxic <br /> Substances Control (DTSC)database. <br /> REGULATION GUIDANCE: A hazardous waste generator shall not treat, store, dispose of,transport or offer for <br /> transportation, hazardous waste without having received an Environmental Protection Agency(EPA)Identification <br /> (ID)Number. A State EPA ID number is required for generators of less than 100 kg RCRA hazardous waste per <br /> month, less than one kg of acutely hazardous waste per month or any amount of non-RCRA hazardous waste. ID <br /> numbers are unique to a business and site location. <br /> CORRECTIVE ACTION: Go to the DTSC web site at https://dtsc.ca.gov/apply-for-hazardous-waste-epa-id-number/ <br /> to obtain a State ID number. Immediately apply for your ID number and submit evidence to the San Joaquin County <br /> Environmental Health Department within 30 days. <br /> This is a Class II violation. <br /> 119 HSC 25404(e)(4)Failed to report program data in the California Environmental Reporting System(CERS). <br /> OBSERVATION: This business's hazardous waste activities have been incorrectly reported on the California <br /> Electronic Reporting System(CERS)website. "YES"is marked on the business activity page for hazardous waste <br /> treatment. No hazardous waste treatment was observed during the inspection. Cesar Quintero, Owner, said that <br /> no hazardous waste treatment occurs at the facility. <br /> REGULATION GUIDANCE: Each regulated business shall report program data electronically on the CERS <br /> website. <br /> CORRECTIVE ACTION: The violation was corrected during the inspection by Cesar making a correct submittal. <br /> This is a Class II violation. <br /> 505 CCR 66262.34(f)Failed to completely label stationary hazardous waste tanks. <br /> OBSERVATION: The 250 gallon hazardous waste tank storing used oil (1/2 full)had a hazardous waste label that <br /> was missing the accumulation start date. <br /> REGULATION GUIDANCE: All hazardous waste tanks shall be marked with the words `Hazardous Waste"and the <br /> accumulation start date. <br /> CORRECTIVE ACTION: Label the hazardous waste tank with the words"Hazardous Waste'and the accumulation <br /> start date. Provide a corrective action statement and supporting documentation to the San Joaquin County <br /> Environmental Health Department(EHD)within 30 days. <br /> This is a Class II violation. p <br /> FA0010812 PRO514422 SCO01 11/18/2019 <br /> EHD 22-01 Rev.9/20/2019 Page 4 of 6 Small Quantity Hazardous Waste Generator OIR <br /> 1868 E. Hazelton Avenue f Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 j wv w.sjcefid.com <br />