My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
401
>
2300 - Underground Storage Tank Program
>
PR0231346
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/9/2020 4:44:13 PM
Creation date
5/19/2020 3:40:21 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0231346
PE
2361
FACILITY_ID
FA0003603
FACILITY_NAME
TESORO (SPEEDWAY XP) 68152
STREET_NUMBER
401
Direction
W
STREET_NAME
KETTLEMAN
STREET_TYPE
LN
City
LODI
Zip
95240
APN
04513019
CURRENT_STATUS
01
SITE_LOCATION
401 W KETTLEMAN LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
118
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNDERGROUND STORAGE TANK <br /> OVERFILL PREVENTION EQUIPMENT INSPECTION REPORT FORM (Page 1 of 1) <br /> Type of Action ❑Installation Inspection ❑Repair Inspection 0 36 Month Inspection <br /> I. FACILITY INFORMATION <br /> CERS ID Date of Overfill Prevention Equipment Inspection <br /> 10181231 2/12/20 <br /> Business Name(Same as Facility Name or DBA-Doing Business As) <br /> Speedway 4945 <br /> Business Site Address City ZIP Code <br /> 401 Kettleman Ln. Lodi 95240 <br /> fl. UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br /> Name of UST Service Technician Performing the Inspection(Print as shown on the ICC Certification.) Phone# <br /> Randy Wilkerson (408)971-2445 <br /> Contractor/Tank Tester License# ICC Certification# ICC Certification Expiration Date <br /> 485184 5258560 1/7/21 <br /> Overfill Prevention Equipment Inspection Training and Certifications(List applicable certifications.) <br /> F.F.#1001093708s � <br /> OPW#100593 <br /> III. OVERFILL PREVENTIONU P <br /> EQ I MENT INSPECTION INFORMATION <br /> Inspection Method m Manufacturer Guidelines(Specify): c 2 20{i' <br /> Used: OPW � Lb 4 10 <br /> ❑Industry Code or Engineering Standard(Specify): <br /> ❑Engineered Method(Specify): ENVIRON"""FeNITAl HEA D�pQr�TltIF��T H <br /> Attach the inspection procedures and all documentation required to determine the results. #of Attached Pages <br /> TANK ID:(By tank number,stored product,etc.) 87 91 <br /> What is the tank inside diameter?(Inches) 98 98 <br /> Is the fill piping secondarily contained? 21 Yes ❑No m Yes ❑No ❑Yes ❑No ❑Yes ❑No <br /> Is the vent piping secondarily contained? Z Yes ❑No ©Yes ❑No ❑Yes ❑No ❑Yes ❑No <br /> Overfill Prevention Equipment Manufacturer(s) OPW OPW <br /> What is the overfill prevention equipment response ®Shuts Off Flow <br /> when activated?when Off Flow El Shuts Off Flow El Shuts Off Flow <br /> (Check all that apply.) ❑Restricts Flow ❑Restricts Flow ❑Restricts Flow ❑Restricts Flow <br /> ❑AIV Alarm ❑AIV Alarm ❑AIV Alarm ❑AfV Alarm <br /> Are flow restrictors installed on vent piping? <br /> ❑Yes m No ❑Yes Q No ❑Yes ❑No ❑Yes ❑No <br /> At what level in the tank is the overfill prevention set <br /> to activate?(Inches from bottom of tank.) 87.75 82.5 <br /> What is the percent capacity of the tank at which the <br /> overfill prevention equipment activates? 96% 91.96% <br /> Is the overfill prevention in proper operating condition ❑Yes 0 Yes ❑Yes ❑Yes <br /> to respond when the substance reaches the <br /> appropriate level? _ la No(Specify in V.) ❑No(Specify in V.) ❑No(Specify in V.) ❑No(Specify in V.) <br /> IV. SUMMARY OF INSPECTION RESULTS <br /> Overfill Prevention Inspection Results ❑Pass m Fail 0 Pass ❑Fail ❑Pass ❑Fail ❑Pass ❑Fail <br /> V. COMMENTS <br /> Any items marked"Fail"must be explained in this section. Any additional comments may also be provided here. <br /> 87 Grade Drop Tube Failed @ 96%.91 Grade Passed but is cut wrong. <br /> VI. CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THIS INSPECTION <br /> I hereby certify that the overfill prevention equipment was Inspected in accordance with California Code of Regulations,Title 23, <br /> Division 3,Chapter 16,Section 2637.2 and all the Information contained herein is accurate. <br /> UST Service Technician Signature r� <br /> Wthe facility has more components than this form accommodates,additional copies of this page maybe attached. <br /> CERS=California En irorrnmtal Reporting System,ID=kientirrcation,UST=Underground Storage Tank,ICC=International Code Council,AN=Audible and Visual <br />
The URL can be used to link to this page