Laserfiche WebLink
At the southwest corner of the site are two water tanks and two pump houses that are used for <br /> fire suppression. Presently there is a small (qe100-gallon) above ground diesel tank, and an <br /> approximately 450-gallon above ground gasoline tank between the two pump houses. Each tank <br /> is staged in secondary containment. <br /> On May 7 I986 an underground storage tank, (UST) used to store regular gasoline, was removed <br /> from the site. It is not clear what the tank size was because conflicting documentation refers to it <br /> as either 300-gallons or 450-gallons. The UST was located immediately behind the present above <br /> ground gasoline tank(Plate 3). There were no records available regarding when the tank was <br /> installed, inventory reconciliation, tank testing, or other operating information. <br /> Site Setting <br /> The Owens-Brockway facility is located at the western edge of the San Joaquin Valley southwest <br /> of the City of Tracy, California. The area is adjacent to the northern Diablo Range of the Coast <br /> Range geomorphic province. In the area, marine sediments striking to the northwest, and dipping <br /> to the northeast characterize the Diablo Range. Alluvial materials eroded from the adjacent <br /> Diablo Range underlie the site. <br /> Groundwater in the area flows generally to the northeast following surface topography. The site <br /> elevation ranges from 140 to 170 feet MSL. A series of groundwater monitoring wells have been <br /> installed at the site to monitor discharges from the wastewater treatment ponds. Groundwater is <br /> encountered at depths ranging from 70 feet below grade at the south end of the site to <br /> approximately 50 feet below grade at the north side of the site. <br /> Previous Investigations <br /> At the time the UST was removed one soil sample was collected from the bottom of the <br /> excavation. The sample was submitted to California Water Labs of Modesto for analysis of total <br /> petroleum hydrocarbons (TPH); aromatic volatile organics by EPA Method 8020;total lead; and <br /> ethylene-dibromide, (EDB). The following summarizes the results of those analyses: <br /> Analyte Result Reporting Limit <br /> Chlorobenzene ND 2.5 <br /> Toluene 192 10.0 <br /> Eth lbenzene 57.8 10 <br /> Benzene 42.5 10 <br /> 1,2-dichlorobenzene ND 2.5 <br /> 1,4-dichlorobenzene ND 2.5 <br /> Xylene ND 2.5 <br /> Lead 15.7 NA <br /> EDB ND 5.0 <br /> TPH 3.9 NA <br /> Owens-Brockway Tracy Report Page 2 March 18,2002 <br /> CKG Environmental,Inc. <br />