Laserfiche WebLink
Former Canteen Facility April 14,2005 <br /> guadefly Groundwater Monitoring Report Page 2 <br /> I • Purged Site monitor wells MW-3, MW-3A, MW-31), MW-11, MW-13, MW-13A and <br /> MW-13B by removing a mizalmum of three well volumes using a Waterra® inertia pump or <br />' disposable bailer <br /> • Sampled and analyzed groundwater for the following parameters <br /> • total petroleum hydrocarbons, gasoline range TPHg)(method 8015 modified), <br />' • benzene, toluene, ethylbenzene, and xylenes (BTEX) and gasoline oxygenates <br /> including t-Butanol (TBA), Methyl-t-Butyl Ether (MTBE), Di-isopropyl Ether (DIPE), <br /> Ethyl-t-Butyl Ether (ETBE), t-Amyl Methyl Ether (TAME), 1,2-dichloroethane (1,2- <br /> DCA), and ethylene dibronude (EDB) (method 826013) <br /> • Preparation of this 2005 First Quarterly Monitoring Report summarizing the findings of <br />' the quarterly activities <br /> This report presents field observations, results, conclusions and recommendations for additional <br />' work, if necessary In addition, a review of the on-site systems operation and maintenance is <br /> presented Delta has prepared this report in accordance with generally accepted environmental <br /> practice <br /> lie <br /> SITE INVESTIGATION & RESULTS <br />' MONITOR WELL SAMPLING <br /> Upon arrival at the Site, the well caps were opened to allow the wells to achieve static <br />' conditions Each well was then gauged to measure groundwater elevations (Table 1) and <br /> selected wells were purged with a Waterra® pump or disposable bailer until three casing <br /> volumes of groundwater had been recovered Field measurements for conductivity, pH and <br />' temperature were taken during purging to ensure the collection of representative formation <br /> groundwater Groundwater samples were collected from seven monitor wells (MW-3, MW-3A, <br />' MW-3D, MW-I 1,MW-13, MW-13A and MW-1313)on March 11, 2005 <br /> During purging of the monitor wells, neither non-aqueous phase liquid (NAPL) nor hydrocarbon <br />' sheen was noted on the purged groundwater A hydrocarbon odor was noted in monitor wells <br /> MW-3 and MW-13 <br />' After purging, samples were collected using pre-cleaned disposable bailers and then transferred <br /> to laboratory provided containers for analysis of TPH(g), BTEX, TBA, MTBE, DIPS, ETBE, <br /> TAME, 1,2-DCA and EDB The samples were transported under chain-of-custody using an <br />' overnight delivery service to Columbia Analytical Services, Inc , of Phoenix, Arizona, a <br /> California accredited analytical laboratory <br /> 1 <br />