Laserfiche WebLink
Table 4 <br /> SVE Pilot Test Data <br /> Compass Group USA,Inc. <br /> 1500 Shaw Road <br /> Stockton, California <br /> Vapor Extraction Well VE-1 Vacuum ("w c) at Observation Well Points <br /> Time Influ!C? <br /> �Wc <br /> cuum Flow Rate PID Reading MWA3 VE-2A VE-2B <br /> ) (scfm) (ppm) (19 5 ft from VE-1) (28 75 ft from VE-1) (28 75 ft from VE-1) <br /> 900 0 0 289 0 0 0 <br /> 930 48 28 623 015 01 01 <br /> 1000 42 28 643 015 01 01 <br /> 1030. 52 39 710 015 01 . 01 <br /> 11001 59 39 646 020 01 01 <br /> 11301 59 39 659 020 01 01 <br /> 1200 92 48 669 025 015 0 125 <br /> 1230 92 48 672 025 015 0125 <br /> 100 91 48 693 0 255 015 0 125 <br /> 130 91 48 667 0 255 015 0 125 <br /> 200 92 48 671 0 255 015 0 125 <br /> 230 93 48 679 025 015 0 125 <br /> 300 93 48 693 025 0 175 015 <br /> 330 93 48 677 0 265 0 175 014 <br /> 400 92 48 709 0 275 0 175 014 <br /> 430 92 48 667 0241 014 0 125 <br /> 500 92 48 729 51 0165, 0 145 <br /> "w c -inches water column <br /> scfm-standard cubic feet per minute <br /> ppm-parts per million <br />