Laserfiche WebLink
Page 2 <br /> Section C Control System <br /> Item 1C 1 DRC U L listed system controller(Nema 4) Per specifications $3,08500 <br /> Each motor circuit to include H/O/A switch, green run light, Motor Starter <br /> w/overload protection, JEC motor contactor, hour meters Red fault indicator <br /> light for each latch circuit <br /> DRC proposes a control panel to include controls for the following <br /> ➢ Air compressor circuit <br /> ➢ (2) High temp switches <br /> ➢ High/low therm-ox temp switch <br /> ➢ SVE blower circuit <br /> ➢ High pressure switch <br /> ,e Solenoid control circuit <br /> ➢ Dry contacts for therm-ox panel connection <br /> ➢ Air/water separator tank high-level latch circuit <br /> ➢ (2) outdoor outlets <br /> Item 2C 2 DRC U L listed system controllers (SVE & Sparge) $2,050 00 ea $4,10000 <br /> Item 3C 1 DRC Telemetry Option with Chester software $3,05000 <br /> DRC TELEMETRY SYSTEM DESCRIPTION <br /> The PLC based control system shall be capable of monitoring up to sixty four digital input channels <br /> and provide a visual indication of each channel The system shall also be capable of monitoring <br /> and controlling up to 32 digital output channels <br /> The system shall be capable of monitoring up to 32 analog input channels and 32 analog output <br /> channels The system shall be capable of initiating the call out sequence needed to activate an <br /> optional auto dialer to alert interested persons to the alarm condition The system shall store alarm <br /> conditions in non-volatile ram to preserve them in a power failure The system shall provide <br /> runtime and cycle count information for all motor outputs The system shall be capable of remote <br /> communication via telephone modem, with a graphic man-machine interface software package <br /> The system shall be capable of remote monitoring of all digital inputs and outputs, remote visual <br /> display of alarms, remote display of analog channel values, remote modification of analog outputs, <br /> remote starting and stopping of critical equipment and remote downloading of operational data <br /> All communications shall use standard phone lines and no leased lines shall be required <br /> SOFTWARE <br /> Manufacturer shall provide software to enable real time monitoring, data acquisition, and complete <br /> process control of all devices in the remedial system Shall enable dialing of remote site Upon <br /> establishing the connection, site configuration information shall be read and screens shall be <br /> generated Shall enable collection of site information in ASCII format which can be used in <br /> standard spread sheets to analyze system performance Detailed help screens shall be provided <br /> and function key operation shall be simple and easy to use and well documented <br /> Diversified Remediation and Controls Inc 6701 Bleck 17nve Rockford,MN 55373 PHONE (763)565-3000 FAX (763)565-3001 www dreJ com <br />