COMPLIANCE INFO_2020
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
P
>
PACIFIC
>
6425
>
2300 - Underground Storage Tank Program
>
PR0231211
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/5/2021 1:26:49 PM
Creation date
5/21/2020 12:39:34 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0231211
PE
2371
FACILITY_ID
FA0002409
FACILITY_NAME
SAFEWAY FUEL CENTER #2707
STREET_NUMBER
6425
Direction
N
STREET_NAME
PACIFIC
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
CURRENT_STATUS
01
SITE_LOCATION
6425 N PACIFIC AVE
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
196
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TS- STS Sump Test. System LEI <br /> Franklin Feeling Syrsttems <br /> Quick Start Guide <br /> TS-STS Overview1 TS-STS Installation <br /> The TS-STS system includes a TS-STS console within a convenient I <br /> portable case,leak testing probes with 50 teat of cable,and probe 1,) Required Materials: <br /> hanging hardware(slip rings and chain). <br /> a.} Tape to secure the probe cable b.) Safety cones& signs <br /> After all fittings within the sump are sealed,the sump is filled with a c.) Grounders,3-pronged extension cord <br /> water-based test solution that covers all sump penetration hales.The <br /> probe is installed so the float is floating on the surface of the test solution. d.) Flat pieces of metal to suspend leak testing probe oversumps <br /> The TS-STS console is quickly programmed with the site name and 2.) Work safely—instal!Safety Cones and Signs at the site <br /> address,number of sumps,the 7-digit code-names for each sump,and <br /> the correct TimefDay/Date before leak testing_ 3_j The probes are precision instruments—handle with care! <br /> Pressing the Fest Ivey at the console keypad starts sump leak tests for d,} The STS probes are shipped with cables attached,do not remove <br /> all sumps.The test time is 15 minutes and tests for a level change the cable from the probe end...remove at the console case only. <br /> greater than 0.002 inches. If the level of a sump drops more than the 5.) Inspect probes for proper float movement before use,then ins#all <br /> leak limit during the test,the Sump Leak Test Report will show a fail probes as shown in Section 1 <br /> result when the test is finished. Leak tests can also be programmed <br /> (scheduled)to start at desired times. 6.) Connect the yellow probe cables to the receptacles at the TS-STS <br /> When finished,leak test reports will automatically print out at the console case.Make sure to rine up keyways before inserting cabfe and <br /> printer. Extra copies of this report can be printed using the report key.A tightening the screw-or?connector <br /> newly completed Sump Leak Test will overwrite the previous results 7.) Locate the TS-STS case outside of the Hazardous Area and tape <br /> stored in memory. Save sump leak test reports and provide copies as the cable dawn to prevent probe movement during the test and to <br /> evidence of compliance wifh regulations. reduce tripping hazards <br /> Recornmendatian: Use a computer and fire Tech version of 8.) Setup f Program the TS-STS console per Saclion 2 <br /> System Sen tine!I to record site data,sump code-names,and fes r <br /> results. Test results can also be extracted from Comm Fort 7 at 9.) Start sump leak test(s)on sumps that are ready <br /> iyOTE the bottom of the T5-SrS console false see section 4). 10,) Always clean,dry,and store probes in the probe carrying case after <br /> 'w Reference Federal and State regulations for leak limit and fest each use <br /> time requirements. Recommendations forlocating the TS-STS <br /> console outside of the fClass i.Division 1,Group a}Hazardous Areas 11.) Test each of i he probes on a monthly basis to ensure ifs ability to <br /> during testing,are based on NFFA3tl,NFFA 30A and NFPA 70 fNECJ, detect leaks.Install the probe in a lest container and initiate a test. <br /> After 5 minutes, remove about 0.12 inches of water.When the test <br /> ,w,cow rrfravo-3oas Re o Feb-mos° :rraki,^ ^s�� comp9etes,the test report should show a Failed result it the probe <br /> Thisdon+�^r^�Y change wi[hwel pnv nalK� INCOH'ixaAegis[ered Trademarfa otFnnklln Fueling Sy SlNnS <br /> is working properly. <br />
The URL can be used to link to this page
Your browser does not support the video tag.