Laserfiche WebLink
it <br /> APPLIED ANALYTICAL <br /> Environmental Laboratories <br /> 3459 Edison Way <br /> Fremont.GA 94538 <br /> (415)623.0775 <br /> ANALYSIS REPORT <br /> Attention: Ms. Eloise Frick Date Sampled: 05-31-90 <br /> Applied GeoSystems Date Received: 06-01-90 <br /> 4191-E Power inn Road BTEX Analyzed: 06-12-90 <br /> Sacramento, CA 95826 TPHg Analyzed: 06-12-90 <br /> Project: AGS 38009-2 TPHd Analyzed: 06-11-90 <br /> Matrix: Water., <br /> Ethyl. Total <br /> Benzene Toluene benzene Xylenes TPHg TPHd <br /> ppb W—h ppb W—b l?h Uh <br /> Detection Limit: 0.50 0.50 0.50 0.50 20 100 <br /> SAMPLE <br /> Laboratory identification <br /> W-38-MW4 ND 1.1° ,ID 1.5' .2401 ND <br /> W1006022 <br /> i <br /> i <br /> ppb = pans per billion =ug/L = micrograms per titer. <br /> ND = Not detected. Compounds)may be present at concentrations below the detection limit. <br /> NR= Analysis not requested. <br /> u A.VALSTIC.41.PROCEDURES <br /> RTEX--Benzene.toluene.erhAbenzene.and total xylene isomers(MT--X)are measured by extraction using EPA.Mcthod 5030 <br /> followed by analysis using FPA Method$0291602.which utilizes a gas chromatograph(GC)equipped with a photoionization detector <br /> (Pit))and a flamc-ionization detector(FID)in series. <br /> TPlig—Total petroleum hydromrbons as gasoline(low-to-mcdium boiling points)arc measured by extraction using EPA Method 5030. <br /> followed by analysis using modified EPA Method 8015,which uniizs a GC equipped with an FID. <br /> TPItd--Total petroleum hydtocatbons as diesel(high boiling points)air measured by extraction using EPA Method 3550 for sods and <br /> CPA Mcihod 3510 for water.followed by modified EPA Method 5015 with direct sample injection into a GC equipped with an FIC. <br /> 06-21-90 <br /> Laboratory Representative Date Reported <br /> APPLIED,%N'ALITICAL LADORATORY 15 CERTIFIED BY TIIE STATE OF C,-,LI FOILNIA <br /> ig DEPARnIE\T OF HEALTH SERVICES AS A HAZARDOUS 1VASTB TESTING t.ABORATORY <br /> (Certification Na. 1531 <br />