Laserfiche WebLink
Historical Background & Site Conceptual Model <br /> FIRE STATION 42 <br />' 110 West Sonora Street, Stockton, California <br />' 1.0. INTRODUCTION <br /> The historical background for the unauthorized release of hydrocarbons from the common <br /> underground storage tank(UST) area at the north end of the property located at 110 West Sonora <br /> Street, Stockton, California is the following <br />' 2.0. <br /> BACKGROUND <br />' The site is bounded on the north by Sonora Street, on the west and south by Madison Street and on <br /> the east by Commerce Street Presently a single building is located at the northern portion of the site, <br />' occupied by the City of Stockton- Fire Prevention Department The properties surrounding the site <br /> are mostly industrial, including the Pacific Gas and Electrical bio-remediation project of the former <br /> coal gasification plant,directly down-gradient east of the site,with a few residences northeast of the <br /> site <br /> 2 1 UNDERGROUND STORAGE TANK REMOVALS <br /> UST installation dates are uncertain, however, the UST likely serviced the training and fire house <br /> site since the 1960's when the facility was constructed The locations of the USTs and tank <br /> designations,as reported by the EHD are depicted on Figure 2 Observe these differ from depictions <br /> of the site UST layout in prior reports <br />' In April 1987,UST 41,a 1,000 <br /> allon gasoline UST was removed from the northern end of the UST <br /> g <br /> cluster located at the western edge of the site The UST removal documented an unauthorized <br /> release This UST reportedly served the western dispenser on the fuel island, located at the <br /> southwestern corner of the building The product line which was served fuel from UST #1 was <br /> reportedly abandoned The soil sample collected during the UST removal reportedly contained total <br /> petroleum hydrocarbons(TPH)at 3,300 milligrams per kilogram(mg/kg),and benzene,toluene and <br /> xylenes at 54 mg/kg, 280 mg/kg and 380 mg/kg, respectively <br /> In August 1987,one additional UST46 was removed from the southern portion of the trained tower, <br /> referred to later as the southern UST In April 1992 UST#4 was removed from the western corner <br /> of the building, this UST stored waste oil and was filled by drain lines from within the building's <br /> repair pit located at the western edge of the building <br /> I In October 1992 UST#2, UST#3 and UST#5 were removed from the site, along with the dispenser <br /> lines which served the site's dispenser located at the southwestern corner of the building UST#5 was <br /> ' a 500 gallon UST used for the storage of diesel fuel UST#2 was a 1,000 gallon gasoline UST and <br /> Advanced GeoEnvironmental,Inc <br /> I <br />