Laserfiche WebLink
San Joaquin Valley <br /> Air Pollution Control District <br /> PERMIT UNIT: N-818-2-2 EXPIRATION DATE: 03/31/2007 <br /> EQUIPMENT DESCRIPTION: <br /> 39.8 MMBTUlHR NEBRASKA BOILER ##2 WITH A LOW-NOX BURNER AND FLUE GAS RECIRCULATION. <br /> PERMIT UNIT REQUIREMENTS <br /> w. I. Particulate matter emissions from any combustion source shall not exceed 0.1 grain&'dscf(calculated to 12% carbon <br /> dioxide). [District Rule 4201] <br /> 2. The boiler shall only be fired on natural gas. [District Rule 2201] <br /> 3. The NOx emissions concentration shall not exceed 30 ppmvd rw. 3% 02 or 0.036 lbs.V1MBTU. The source test plan <br /> shall identify which basis will be used to demonstrate compliance. [District Rule 43051 <br /> 4. CO emissions concentration shall not exceed 400 ppmv, dry, corrected to 3% 02. [District Rule 4305] <br /> 5. The PM10 emission concentration shall not exceed 0.014 lb/MMBTU. [District Rule 2201] <br /> L. 6. The SOx emission concentration shall not exceed 0.0006 lb/NEIABTU. [District Rule 220I] <br /> 7. The VOC emission concentration shall not exceed 0.00281b/MMBTU. [District Rule 2201] <br /> v 8. Sampling facilities for source testing shall be provided in accordance with the provisions of Rule 1081 (Source <br /> Sampling), [District Rule 1081] <br /> 9. Source testing to demonstrate compliance with NOx and CO limitations shall be conducted as required by Section 6.3 <br /> of Rule 4305: Boilers, Steam Generators, and Process Heaters. [District Rule 4305] <br /> 10. Source testing shall be conducted using the methods and procedures approved by the District.The District must be <br /> notified 30 days prior to any compliance source test, and a source test plan must be submitted for approval 15 days <br /> prior to testing. [District Rule 1081] <br /> 11. The results of each source test shall be submitted to the District within 60 days thereafter. [District Rule 108 1] <br /> 12. Source testing to measure concentrations of oxides of nitrogen (as NO2) shall be conducted using EPA method 7E or <br /> CARB method 100. [District Rule 4305] <br /> 13. Source testing to measure concentrations of carbon monoxide(CO)shall be conducted using EPA method 10 or <br /> *� CARB method 100. [District Rule 4305] <br /> 14. Source testing to measure the stack gas oxygen shall be conducted using EPA methods 3 or 3A. or CARS method 100. <br /> [District Rule 4305] <br /> 15. The acceptable minimum flue gas recirculation rate shall be established by testing emissions from this unit or other <br /> representative units as approved by the District. The acceptable flue gas recirculation rate shall be the minimum flue <br /> low gas recirculation rate with which compliance with applicable NOx and CO emissions limits have been demonstrated <br /> through source testing at a similar firing rate. [District Rule 4305] <br /> 16. The flue gas recirculation rate shall be determined at least on a weekly basis by measuring the stack temperature (Ts), <br /> Lo windbox temperature(Tw), and ambient temperature(Ta) and using the following equation: FGR rate= f(Tw- <br /> Ta)/(Ts -Ta))*I00% [District Rule 43051 <br /> PERMIT UNIT REQUIREMENTS CONTINUE ON NEXT PAGE <br /> These terms and conditions are part of the Facility-wide Permit to Operate. <br /> �-• Facility Name: CALIFCRN;A STATE UNIVERSITY <br /> Location: 1208 N STATE ST.STOCKTON.CA 95202 <br />