Laserfiche WebLink
TPH-g was detect in soil sample collected from CPTI at 78 feet bsg at a concentration of <br /> 4,800 mg/kg, in addition, toluene, ethylbenzene and xylene and were detected at maximum <br /> concentrations of 350 mg/kg TPH-d and benzene were not detected In the sample from 78 feet bsg <br /> HUI One sample (CPT5-60) was collected from off-site CPT5, target analytes were not detected <br /> in tlus sample <br /> HU2 One sample (CPT3-60) was collected from westernmost boring CPT3, target analytes were <br /> not detected in this sample <br /> HU4 Samples CPT 1-100,CPT2-97,CPT3-108,CPT4-105 and CPT5-108 were collected from flus <br /> HU TPH-g was detected at concentrations of 1,500 micrograms per liter(µg/1)in CPT I-100 and 210 <br /> µg/1 in CPT2-97 The BTEX compounds toluene, ethylbenzene and xylenes were detected at <br /> maximum concentrations of 14 µg/1 (CPT2-97), 13 µg/l (CPTI-100) and 80 µg/1 (CPTI-100), <br /> respectively No other analytes were detected in the samples analyzed <br /> HU5 One sample (CPT3-124) was collected from westernmost boring CPT3, target analytes were <br /> not detected in this sample <br /> HU5 Samples CPTI-124, CPT2-124 and CPT4-124 were collected from flus HU TPH-g was <br /> detected in samples CPTI-124 and CPT'.'--124 at a maximum concentration of 14,000 µg/1 <br /> (CPT2-124),in addition,TPH-d was detected 1n sample CPT2-124 at 5,200µg/I BTEX compounds <br /> were detected at max�mu�•n concentrations of 55 µg/l benzene, 840 µg/1 toluene, 460 µg/1 <br /> ethylbenzene and 2,000 µg/1 xylenes, in sample CPT2-124 In addition, the fuel additive 1,2-DCA <br /> was detected in sample CPTI -124 at 2 1 µg/l No other aaa=ytes were detected in the samples <br /> analyzed <br /> HU7 One sample (CPT3-150)was collected from westernmost bonng CPT3, target analytes were <br /> not detected in this sample <br /> HU8 Samples CPTI-150, CPT2-150, CPT4-145 and CPT5-150 were collected from this HU <br /> TPH-g was detected in samples CP R-150, CPT2-150 and CPT5-150 at a maximum concentration <br /> of 11,000 µg/I (CPT2-150), in addition, TPH-d was detected in samples CPTI-150 and CPT2-150 <br /> at a maximum concentration of 5,300 µg/1 (CPTI-150) BTEX compounds were detected in <br /> CPTI-150, CPT2-150 and CPT5-150 at maximum concentrations of 35 µg/1 benzene, 590 µg/l <br /> toluene, 360 µ.g/1 ethylbenzene and 1,700 µg/1 xylenes, in sample CPT2-150 In addition, the fuel <br /> additive 1,2-DCA was detected in sample CPT2-150 at 2 8 µg/1 No other analytes were detected in <br /> the samples analyzed <br /> An additional grab ground water sample (CPT2-185) was collected at a depth of 185 feet bsg, <br /> approximately 25 feet below the limit of CPT soil data TPH-g was detected in this sample at a <br /> concentration of 130µg/l In addition,BTEX compounds were detected at concentrations of 17 µ.g/1 <br /> benzene, 2 3 µg/1 toluene and 2 2 µg/1 xylenes No other analytes were detected <br /> Advanced GeoEnvironmental <br />