My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_XR0008673 CASE 1
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
2375
>
2900 - Site Mitigation Program
>
PR0505512
>
ARCHIVED REPORTS_XR0008673 CASE 1
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/28/2020 2:52:50 PM
Creation date
5/28/2020 2:39:29 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0008673 CASE 1
RECORD_ID
PR0505512
PE
2950
FACILITY_ID
FA0006827
FACILITY_NAME
BP/MOBIL SERVICE STATION
STREET_NUMBER
2375
Direction
N
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
TRACY
Zip
95376
APN
23207003
CURRENT_STATUS
02
SITE_LOCATION
2375 N TRACY BLVD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
LSauers
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
35
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SP EXPLORATION & OIL, INC. <br /> • ENVIRONMENTAL RESOURCE MANAGEMENT <br /> DATA REVIEW CHECKLIST <br /> BP Site Number 11224 <br /> ERM Contact H177179 <br /> Sampling Date 3/17/98 <br /> Matrix Description Water <br /> Date Final Report Received 3/30/98 <br /> Laboratory & Location SPL, Houston, Texas <br /> Yes No N/A <br /> 1 Is BP contract release number <br /> consistent with analytical report? —X- <br /> 2 Was report submitted within the <br /> specified timeframe? —X- <br /> 3 Does report agree with the COC? —X- <br /> 4 Are units consistent with the given matrix? —X- <br /> 5 Were any target analytes/compounds <br /> detected in blanks (i e, trip or equipment)? —X- <br /> 6 Are duplicate water samples within 30%7 <br /> 7 Are holding tunes met? X-- <br /> 8 Are surrogates within limits using laboratory <br /> criteria? —X- <br /> 9 Are MS/MSD acceptable using laboratory See Below <br /> criteria? <br /> 10 Are LCS results acceptable using laboratory <br /> criteria? --X— <br /> MS/MSD relative % difference values for BTEX in one of two matrix spikes was outside QC <br /> range due to matrix interference MS/MSD linuts are advisory only, as stated in SW-846, <br /> Section 8 7 to 8 8, if the MS/MSD results fall outside the advisable ranges, a laboratory <br /> control samples (LCS) must be analyzed and fall within those ranges LCS results are within <br /> quality control limits <br /> Data Validation Completed by Brad Nagle <br /> (signature) <br /> Date <br /> ly• <br />
The URL can be used to link to this page
Your browser does not support the video tag.