'12/05/2000 17:10 FAX 200 9480 21 11011 <br /> JU KLEINFELDER <br /> sampling depth where groundwater is encountered. A stainless steel drive tip equipped with a <br /> stainless steel filter is lowered into the boring at the end of a 2.5-inch diameter galvanized steel <br /> pipe and pushed using the drill rig approximately 6 to 12 inches into the soil/aquifer formation at <br /> the bottom of the boring. A sterilized, glass, vacuum scaled sampling ampoule (tube), similar to <br /> a standard volatile organics (VOA) vial, is then lowered through the pipe down to the tip with a <br /> cable. Between the tip and the sample tube is a double-sided hypodermic needle (syringe), <br /> which simultaneously punctures the seals on the stainless steel drive tip and the septum of the <br /> glass sample ampoule. The vacuum in the sample ampoule draws groundwater through the lip <br /> into the glass ampoule. The glass ampoule is then pulled out of the pipe, disengaging the <br /> syringe_ The septum in the glass ampoule and drive tip reseals after the syringe is removed. <br /> To reduce the potential for introducing contaminants into the samples, the drive tip, galvanized <br /> pipe, and other equipment used for sample collection are steam cleaned and/or washed with <br /> trisodium phosphate or non-phosphate detergent solution and double rinsed with distilled water <br /> prior to use. The sample probe and filters are cleaned in TSP solution and rinsed with methyl <br /> alcohol followed by a distilled water tinse prior to use. New, factory-sterilized syringe needles, <br /> 0•rings,septums and sample tubes are used for each sample. <br /> B-2.6 Sample Handling . <br /> Anes labeling, the sample is immediately stored in an iced cooler for transport to Kleinfelder's <br /> office sample control or to the analytical laboratory. A Kleinfelder chain-of-custody form <br /> accompanies the cooler. The chain-of-custody form includes Kleinfelder's name, address and <br /> telephone number, the employee number of the individual who performed the sampling, the <br /> sample numbers, the date and time the samples were collected, the number of containers each <br /> sample occupies, the sample matrix (soil or water) and the analyses for which the samples are <br /> being submitted, if any. The chain-of-custody form is signed by each person who handles the <br /> samples, including all Kleinfelder employees and the receiving employee of office sample <br /> control or t1le analytical laboratory when the samples are delivered. <br /> B-2.7 Decontamination of Equipment <br /> To reduce the potantial for cross-contarnination, augers and associated equipment are steam <br /> cleaned prior to drilling each boring. In addition, sampling equipment is cleaned with a <br /> trisodiurn phosphate or non-phosphate detergent wash and rinsed with distilled water prior to <br /> collecting each soil sample. <br /> 01001PROPM ViaTO 3P443 Dae:mhr. 5,2003 <br /> 2002 Klmafcldc;Inc. Page iii rof;x <br /> h:nA! x"�y' Cc1 iz_.v1.sY _ 1 wc3 r4 if. .'}y -.C '1". `aa�,'r'-..4.'•-.r= 5-uf, S.;Av�6^�"wtk'^ " k'ti <br />