Laserfiche WebLink
A J OA U I Environmental Health Department <br /> COUNTY <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> QUIK STOP MARKET#3132* 3555 W HAMMER LN, STOCKTON April 15, 2020 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 209 CCR 2716(a-e) Failure to conduct the designated UST operator visual inspection at least once every 30 days. <br /> OBSERVATION: The designated operator failed to check and note all required items on the visual inspection <br /> reports. The incorrect and missing information included the following from the inspection reports: <br /> -The 1/24/2020, 4/6/2020 and 12/24/2019, 9/23/2019, 8/27/2019, 7/29/2019 DO reports, The OWNER/ <br /> OPERATOR failed to provide a name, signature, and date within 48 hours of receiving the DO report under the <br /> ACKNOWLEDGMENT OF COMPLIANCE ISSUES section VI. <br /> -The 2/10/2020 and 3/9/2020 DO reports, did not include the owner/operator name in section VI. <br /> -The 10/21/2019, 9/23/2019, 8/27/2019, 7/29/2019, 6/3/2019 DO reports, The DO failed to add a description in <br /> section III to all components marked NA from section VII through XI. <br /> REGULATION GUIDANCE: During the visual inspection, the designated operator shall check that all required <br /> testing and maintenance for the UST system have been completed and shall check all required items on the report. <br /> CORRECTIVE ACTION: Ensure that designated operators performing visual inspections at this facility are including <br /> all of the required information on the reports. <br /> This is a minor violation. <br /> 215 CCR 2712(1) Failure to retain a copy of the permit to operate at the facility. <br /> OBSERVATION: A copy of the UST operating permit was not found on site. <br /> REGULATION GUIDANCE: A copy of the UST operating permit and all attachments and conditions shall be <br /> retained at the facility. <br /> CORRECTIVE ACTION: Immediately obtain a copy of the permit and retain it on site. <br /> This is a minor violation. <br /> 313 HSC 25290.1, 25290.2, 25291 Failure to construct, operate, and maintain primary containment as product-tight. <br /> OBSERVATION: Seepage was detected below the shear valve in under dispenser containment (UDC) 3/4 , <br /> indicating a leak in the primary containment. <br /> REGULATION GUIDANCE: All primary containment for the UST system must be product tight. <br /> CORRECTIVE ACTION: Immediately have a properly licensed, trained, and certified contractor repair or replace the <br /> failed component(s), under permit and inspection of the EHD if necessary. <br /> This is a minor violation. <br /> FA0002232 PR0231130 SCO01 04/15/2020 <br /> EHD 23-01 Rev.9/20/2019 Page 5 of 6 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />