Laserfiche WebLink
=NVIF <br />77 71 77 UNDERGROUND STORAGE TANK <br />SECONDARY CONTAINMENT TESTING REPORT FORM (Page 1 of 6) <br />Fype Action ❑ Installation Test <br />® Repair Test ❑ Six Month Test ❑ 36 Month Test <br />I. FACILITY INFORMATION <br />CERS ID <br />10181229 <br />Date of Secondary Containment Test <br />12/12/2020 <br />Business Name (Same as Facility Name or DBA -Doing Business As) <br />Speedway 4873 <br />Business Site Address <br />35 N. Cherokee Ln. <br />City <br />Lodi <br />ZIP Code <br />95240 <br />II. UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br />Name of UST Service Technician Performing the Test (Print as shown on the ICC Certification) <br />Eusebio Sousa <br />Phone # <br />(707) 545-5522 <br />Contractor / Tank Tester License # <br />Able Maintenance, Inc. - 312844 <br />ICC Certification # <br />5454516 <br />ICC Certification Expiration Date <br />7/12/2021 <br />III. SUMMARY OF SECONDARY CONTAINMENT TESTING RESULTS <br />TANK ID: (By tank number, stored product, etc.) <br />A B <br />C <br />D <br />Tank Containment <br />Tightness Test Result <br />❑ Pass ❑ Fail m NA ❑ Pass ❑ Fail ❑ NA <br />❑ Pass ❑ Fail ❑ NA <br />❑ Pass ❑ Fail ❑ NA <br />Product Piping Containment <br />Tightness Test Result <br />❑ Pass ❑ Fail m NA ❑ Pass ❑ Fail ❑ NA <br />❑ Pass ❑ Fail ❑ NA <br />❑ Pass ❑ Fail ❑ NA <br />Communication Test Result <br />❑ Pass ❑ Fail m NA ❑ Pass ❑ Fail ❑ NA <br />❑ Pass ❑ Fail ❑ NA <br />❑ Pass ❑ Fail ❑ NA <br />Remote Fill Piping Containment <br />Tightness Test Result <br />❑ Pass ❑ Fail m NA ❑ Pass ❑ Fail ❑ NA <br />❑ Pass ❑ Fail ❑ NA <br />❑ Pass ❑ Fail ❑ NA <br />Communication Test Result <br />❑ Pass ❑ Fail la NA ❑ Pass ❑ Fail ❑ NA <br />❑ Pass ❑ Fail ❑ NA <br />❑ Pass ❑ Fail ❑ NA <br />Vent Piping Containment <br />Tightness Test Result <br />❑ Pass ❑ Fail 0 NA ❑ Pass ❑ Fail ❑ NA <br />❑ Pass ❑ Fail ❑ NA <br />❑ Pass ❑ Fail ❑ NA <br />Communication Test Result <br />❑ Pass ❑ Fail m NA ❑ Pass ❑ Fail ❑ NA <br />❑ Pass ❑ Fail ❑ NA <br />❑ Pass ❑ Fail ❑ NA <br />Vapor Recovery Piping Containment <br />Tightness Test Result <br />❑ Pass ❑ Fail m NA ❑ Pass ❑ Fail ❑ NA <br />❑ Pass ❑ Fail ❑ NA <br />❑ Pass ❑ Fail ❑ NA <br />Communication Test Result <br />❑ Pass ❑ Fail m NA ❑ Pass ❑ Fail ❑ NA <br />❑ Pass ❑ Fail ❑ NA <br />❑ Pass ❑ Fail ❑ NA <br />Turbine / Product Piping Sump <br />Tightness Test Result <br />❑ Pass ❑ Fail la NA ❑ Pass ❑ Fail ❑ NA <br />❑ Pass ❑ Fail ❑ NA <br />❑ Pass ❑ Fail ❑ NA <br />Fill Riser Sump <br />Tightness Test Result <br />VENT I TRANSITION SUMP ID: <br />❑ Pass ❑ Fail 0 NA ❑ Pass ❑ Fail ❑ NA <br />a b <br />❑ Pass ❑ Fail ❑ NA <br />C <br />❑ Pass ❑ Fail ❑ NA <br />d <br />Tightness Test Result <br />❑ Pass ❑ Fail m NA ❑ Pass ❑ Fail ❑ NA <br />❑ Pass ❑ Fail ❑ NA <br />❑ Pass ❑ Fail ❑ NA <br />UDC ID: <br />13/4 2 <br />3 <br />4 <br />Tightness Test Result <br />m Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑ NA <br />❑ Pass ❑ Fail ❑ NA <br />❑ Pass ❑ Fail ❑ NA <br />UDC ID: <br />5 6 <br />7 <br />8 <br />Tightness Test Result <br />UDC ID: <br />❑ Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑ NA <br />9 10 <br />❑ Pass ❑ Fail ❑ NA <br />11 <br />❑ Pass ❑ Fail ❑ NA <br />12 <br />Tightness Test Result <br />❑ Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑ NA <br />❑ Pass ❑ Fail ❑ NA <br />❑ Pass ❑ Fail ❑ NA <br />All items marked "Fail" or "NA" must be explained in their respective "COMMENTS" section. <br />IV. CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THIS TESTING <br />I hereby certify that the secondary containment was tested in accordance with California Code of Regulations, Title 23, Division <br />3, Chapter 16, Section 2637 and all the information contained herein is accurate. <br />UST Service Technician Signature <br />CERS = California Environmental Reporting System, ID = Identification, UST = Underground Storage Tank, ICC = International Code Council, NA = Not Applicable, UDC = Under - <br />Dispenser Containment <br />