Laserfiche WebLink
VVZp <br /> ® INC <br /> Total Organic Vapors <br /> ' 0 ppm or "background" (BG) Level D PPE <br /> ' Above BG to 5 ppm breathing zone Level C PPE <br /> 5-500 ppm breathing zone Level B PPE <br /> 500-1000 ppm breathing zone Level A PPE <br /> >1 ppm breathing zone Evacuate <br /> Inorganic Gases (H2S, HCN) <br /> i <br /> Background to 5 ppm breathing zone Level D PPE <br /> 5-40 ppm breathing zone Level B PPE <br /> >40 ppm breathing zone Level A PPE or evacuate <br /> Flammable Gases and Vapors <br /> Background Level D PPE <br /> BG-20% LEL Level D PPE if methane, <br /> evacuate if organic vapors also read > 1000 ppm <br /> >20% LEL Ventilate below 20% LEL, stop work 1f <br /> unsuccessful <br /> Oxygen <br /> ' 195%-21% Level D or Level C PPE <br /> X19 5% Level B PPE <br /> • APPENDIX 1 <br /> 13 <br /> 08220010 005 <br />