_ AME <br /> Engineers and Eadh ScienBsts <br /> RECEIVED <br /> May 25, 2011 MvIAY 2 6 2011 <br /> ENVIRONMENTAL HEALTH <br /> Mr. Gerald Djuth, C.E.G., P.E. PERMIT/SERVICES <br /> California Regional Water Quality Control Board <br /> 11020 Sun Center Drive, #200 <br /> Rancho Cordova, California 95670-3291 16014.01/1 <br /> Subject: Work Plan for Well Destruction <br /> Former Georgia-Pacific Tracy Chemical Packaging Plant <br /> 75 W. Valpico Road, Tracy, California <br /> Dear Mr. Djuth, <br /> On behalf of Georgia-Pacific, LLC (G-P), in compliance with the California Regional Water <br /> Quality Control Board, Central Valley Region (RWQCB) letter dated April 26, 2011, Acton • <br /> Mickelson • Environmental, Inc. (AME) has prepared this Work Plan for Well Destruction <br /> (Work Plan) for the former Tracy Chemical Packaging Plant located at 75 W. Valpico Road, <br /> Tracy, California (site; Figures 1 and 2). The drilling activities described herein are part of well <br /> destruction activities that will be conducted at the site in general accordance with San Joaquin <br /> County Environmental Health Department (San Joaquin County) requirements. Soil and ground <br /> water at the site had been impacted by chloroform from past operations; however, the RWQCB <br /> has found that no further action will be required after the 33 existing site wells have been <br /> destroyed. <br /> OBJECTIVES <br /> The objective of the work described herein is to destroy 21 ground water monitoring wells by <br /> pressure grouting, and 12 ozone sparging wells by over-drilling. <br /> SCOPE OF WORK <br /> The proposed work consists of pressure grouting 21 monitoring wells (ranging in diameter from <br /> 2 to 8 inches and extending from 28.5 to 82.0 feet below ground surface [bgs]) using Type I/II <br /> cement grout tremmied into the well. The monitoring wells are completed with standpipes and <br /> flush mounts, which will be removed along with annular and native material to a depth of 3 feet <br /> bgs at a diameter of 12 inches larger than the original boring of the destroyed well. The casing <br /> will be cut at a depth of 2.5 feet bgs or greater and removed from the boring. The boring will be <br /> filled with cement grout to a depth of 2 feet bgs, and a pressure of 25 pounds per square inch will <br /> ©2011. Georgia-Pacific LLC. All rights reserved. <br /> UA2011 Letters and Reports\16014.01\Work Plans\Well Destruction\Work Plan.doc <br /> Acton • Mickelson • Environmental, Inc. www.ameinc.net <br /> 1107 Investment Blvd, #290 (916) 939-7550 <br /> EI Dorado Hills, California 95762 Fax (916) 939-7570 <br />