5 <br /> �. ME UM VERIFICATION LABORATORY A�.YSIS <br /> TANK TANK TPH-G TPH-D BTX & E CL HC TOTAL MTBE METALS PCB <br /> +Y CONTENTS 8015 8015 8020 8010 LEAD TBA; ICRP/ 8270 <br /> 8260 8260 8260 8240 7420DIPS, AES or 8080 <br /> 7421 ETRE, AA <br /> TAME <br /> 8260 <br /> LEADED GAS X X X X <br /> �3. UNL GAS X <br /> X X <br /> DIESEL X X <br /> C KEROSENE X X <br /> UNK FUEL X X X X X <br /> PROD. OIL <br /> X X <br /> CHLOR. <br /> SOLVENTS X 7{ j <br /> NONCHLOR ' <br /> SOLVENTS X X X s <br /> WASTEI C. <br /> USED OIL X X X X X. X <br /> All analysts methods are the designated EPA methods described in EPA SW 846, Third Edition. Those methods not'found in <br /> SW 846 are specifically noted below. Refer to the "SWRCB LUFT Field Manual". Appendix D(B), Table 3-5 on page A20 for <br /> minimum detection limits for motor vehicle fuel (gasoline and dieseI). Refer to 1-2-3 "Regional Board Staff Recommendations <br /> for Initial Evaluation and Investigation of UST's" for the waste and motor oil minimum detection limits. <br /> Detection Linins that retrain below the MCL, STLC or Allowable Limit of the contaminant in question will be accepted, <br /> however labaratoty shall utilize the most conservative"method. <br /> LABORATORY.ANALYSES TERMINOLOGY: <br /> TPH-G Total Petroleum Hydrocarbon, Gasoline, GC/FID(5030)8015 mod or GC/MS 8260 j <br /> TPH-D Total Petroleum Hydrocarbon, Diesel, GC/FM(3550), 8015 mod or GC/MS 8260 <br /> BTX&E Benzene, Toluene, Xylene&Ethyl Benzene, GC/PID 8020 or GC/MS 8260 <br /> CL HC Chlorinated Hydrocarbon, GC/HSD 8010, GC/MS 8240 <br /> TOTAL LEAD i: Total lead, AA 7420, AA 7421 or ICP-AES 6010 <br /> MTBE,TAME,DIPE,TBA GC/MS 8260 <br /> METALS ICRP ar AA Inductively Coupled Plasma Atomic Emission Spectrometry 6010 or Atomic Absorption Spectrometry 7000. <br /> Metals:Cadmium, Chromium III and VI, Lead, Zinc and Nickel. <br /> PCH Polychlorinated Biphenyls, GCIMS 8270 or 8080 <br /> GC-FID Gas Chromatography, Flame Ionization Detection <br /> Method 3050 Acid digestion <br /> Method 3540 Soxhlet sample preparation <br /> Method 3550 Sonication sample preparation, extraction method <br /> Method 5030 Purge and trap sample preparation <br /> QA/QC Quality Assurance/ <br /> Quality Control <br /> Notes: To avoid false positive detection of benzene, benzene-free solvents are to be used. Fused capillary columns are preferred to packed <br /> columns; a packed column may be used as a "first cut" with "dirty" samples or once the hydrocarbons have been characterized and proper <br /> QA/QC is followed. <br /> For drinking water sources, EPA recommends that the 500 series!for volatile organic should be used in preference to the 600 series because the <br /> detection limits are lower and the QA/QC is better. Samples exhibiting any level of heavy metal contamination may require further analysis. <br /> PHS-EHD recomriends holding those samples until disposal is indicated. <br /> EH 23 046 (Revised 10119/98) page 8 <br />