Laserfiche WebLink
S.�.N �aAQU I N L dC,�� HEA'C..TH D 2 S TR I CT <br /> TANK CLOSURE PLAN REVIEW CHECKLIST - MINIMUMxVERIFICATION LAB ANALYSES <br /> TANK TANK CONTENTS TPH-G TPH-D TEPH BTX&S � CL HC TEL EDB METALS PCB <br /> ID # Waste Product GC-FID GC-FID (3550) (8020) (8010) ( S) (ICP- (8270) ' <br /> (5030) (5030) (3540) (8240) AES) (8080) <br /> r LEADED GASOLINEX � <br /> _._ZX <br /> DIESEL_ —___ __ _.__ ._. _ —•-- _X _x <br /> KEROSENE <br /> UNKNOWN FUEL <br /> OIL - <br /> CHLOR. SOLVENTS ___....__.._..-- __- _-_-•- ...-....__.__._.. _ ......____-- ..�-.._.__..... ._._.._.... _ __ <br /> NONC14L O R. SOLVTS <br /> WASTE/USED OIL <br /> ---_. <br /> MINIMUM VERIFICATION LABORATORY ANALYSES TERMINOLOGY '. <br /> The following listing of laboratory analysQs abbreviations is provided as a guide so that <br /> terminology used vili be more familiar. Ail analyysses methods are designated EPA methods as <br /> described in EPA SW 846, Third Edition. Those methodsj'not found in SW 846, are <br /> specifically noted. <br /> TPH G Total Petroleum Hydrocarbon, Gasoline <br /> TPH D Total Petroleum Hydrocarbon, Diesel <br /> TLIPH Total Extractable Petroleum Hyyd�rocarbon (8015) <br /> BTX & E (8020) Benzene, Toluene, Xylene & Ethyl Benzene (8020) <br /> CL HC 8010 OR 8240 Chlorinated Hydrocarbon 8010 or 8240 <br /> TEL (DOHS-LUFT) Tetraethyl Lead (DOHS-LIFT) Ei <br /> EDB (DOHS--AB 1803) Ethylene dibromide (DOHS-AB 1603) <br /> GC FID Gas Chromatography Flame Ionization Detector <br /> ICP-AES OR AA Inductively Coupled Plasma Atomic Emission Spectrometry or Atomic <br /> Absorption Spectrometry <br /> Method 5030 Purge and Trap Sample Preparation <br /> Method 3550 Sonication Sample reparation ;; <br /> Method 3540 Soxhlet Sample preparation <br /> QA/QC Quality Assurance/Quality Control <br /> `f <br /> Notes: To avoid false positive detection of benzene, benzene-free solvents are to be used. <br /> Fused capillary columns are preferred to asked columns; a packed column may be used as a <br /> "first Cut" wi -h "dirty" samples or once Che hydrocarbons have been characterized and <br /> proper QA/QC is followed. <br /> For Drinking Water Sources EPA recommends that the 500 series for volatile <br /> organics be used in preference to the 600 series because the detection limits are lower and <br /> the QA/QC is better. <br /> SITE ADDRESS 100 Valpico Road, Tracy, California SWEEPS # l `7 <br /> CONTRACTOR Precision Industries, Inc. APPROVAL DATE <br /> 0 <br />