COMPLIANCE INFO_2020
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
1301
>
2300 - Underground Storage Tank Program
>
PR0231342
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/7/2020 11:03:53 AM
Creation date
6/1/2020 2:04:22 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0231342
PE
2361
FACILITY_ID
FA0000392
FACILITY_NAME
FLAMES LIQUOR
STREET_NUMBER
1301
Direction
W
STREET_NAME
KETTLEMAN
STREET_TYPE
LN
City
LODI
Zip
95242
APN
03104030
CURRENT_STATUS
01
SITE_LOCATION
1301 W KETTLEMAN LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
44
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Underground Storage Tank <br />Secondary Containment Testing Report Form <br />8. SUMP/UDC TEST <br />Test Method Developed by ❑ Manufacturer ❑ Industry Standard ® Professional Engineer <br />Test Type ❑ Pressure ❑ Vacuum ® Hydrostatic <br />Test Equipment Used: Caldwell Level Change Indicator <br />Sump/UDC ID <br />1 -87 -PS <br />2 -91 -PS <br />3 -Diesel -PS <br />Bravo SYCS <br />Sump Manufacturer <br />Unknown <br />Unknown <br />Unknown <br />10" <br />Sump Depth (inches) <br />60 1/2" <br />60" <br />60" <br />BP <br />Sump Bottom to Top of <br />Highest Pipe Penetration <br />(inches) <br />13" <br />14 1/2" <br />14" <br />8:52 <br />Test Start Time <br />8:37 <br />10:07 <br />8:42 <br />.001 <br />Initial Reading <br />.001 <br />.001 <br />.001 <br />9:22 <br />Test End Time <br />9:07 <br />10:37 <br />9:12 <br />.001 <br />Final Reading <br />.001 <br />.001 <br />.001 <br />0 <br />Change in Reading <br />0 <br />0 <br />0 <br />> .002 <br />Pass /Fail Criteria <br />>.002 <br />>.002 <br />>.002 <br />® Pass ❑ Fail <br />Tightness Test Results <br />M Pass ❑ Fail <br />® Pass ❑ Fail <br />® Pass ❑ Fail <br />❑ Pass ❑ Fail <br />Sump/UDC ID <br />UDC 1&2 <br />UCD 3&4 <br />UCD 5&6 <br />UCD 7&8 <br />Sump Manufacturer <br />Bravo SYCS <br />Bravo SYCS <br />Bravo SYCS <br />Bravo SYCS <br />Sump Depth (inches) <br />10" <br />10" <br />10" <br />10" <br />Sump Bottom to Top of <br />Highest Pipe Penetration <br />(inches) <br />BP <br />BP <br />BP <br />BP <br />Test Start Time <br />8:47 <br />8:57 <br />8:52 <br />9:02 <br />Initial Reading <br />.001 <br />.001 <br />.001 <br />.001 <br />Test End Time <br />9:17 <br />9:27 <br />9:22 <br />9:32 <br />Final Reading <br />.001 <br />.001 <br />.001 <br />.001 <br />Change in Reading <br />0 <br />0 <br />0 <br />0 <br />Pass/Fail Criteria <br />> .002 <br />> .002 <br />> .002 <br />> .002 <br />Tightness Test Results <br />® Pass ❑ Fail <br />® Pass ❑ Fail <br />® Pass ❑ Fail <br />® Pass ❑ Fail <br />Additional copies of this page may be attached. <br />All tests marked "Fail' and any repairs made before or during the tightness test must be described in <br />the COMMENTS section. <br />Page 3 of 5 <br />