My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
A
>
ACACIA
>
525
>
2800 - Aboveground Petroleum Storage Program
>
PR0526379
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/24/2020 1:59:24 PM
Creation date
6/2/2020 3:00:01 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0526379
PE
2832
FACILITY_ID
FA0002864
FACILITY_NAME
DAMERON HOSPITAL
STREET_NUMBER
525
Direction
W
STREET_NAME
ACACIA
STREET_TYPE
ST
City
STOCKTON
Zip
95203
APN
13715304
CURRENT_STATUS
01
SITE_LOCATION
525 W ACACIA ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
104
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Are all valves free of leaks, corrosion and other <br /> damage?Follow manufacturers' instructions for <br /> regular maintenance of these items. Check the <br /> following and verify(as applicable): <br /> ❑Anti-siphon valve ❑Yes ❑No Ll N/A <br /> 16 ❑Check valve ❑Yes El No Ll N/A <br /> ❑Gate valve []Yes El No El N/A <br /> ❑ Pressure regulator valve []Yes El No El N/A <br /> ❑ Expansion relief valve <br /> ❑Solenoid valve ❑Yes ❑No Ll N/A <br /> ❑ Fire valve ❑Yes ❑No Ll N/A <br /> ❑Shear valve []Yes El No El N/A <br /> 17 Are strainers and filters clean and in good condition? []Yes ❑NO ❑N/A <br /> Insulated Tanks <br /> Free of missing insulation? ❑Yes ❑NO ❑N/A <br /> 18 Insulation free of visible signs of damage? <br /> Insulation adequately protected from water intrusion? <br /> 19 Insulation free of noticeable areas of moisture? ❑Yes ❑NO ❑N/A <br /> 20 Insulation free of mold? ❑Yes ❑NO ❑N/A <br /> 21 Free of visible signs of coating failure? ❑Yes ❑NO ❑N/A <br /> Tank/Piping Release Detection <br /> 22 Is inventory control being performed and documented ❑Yes ❑NO ❑N/A <br /> if required? <br /> 23 Is release detection being performed and documented ❑Yes ❑NO El N/A <br /> if required? <br /> Other Equipment <br /> 24 Are electrical wiring and boxes in good condition? []Yes ❑NO ❑N/A <br /> Has the cathodic protection system on ❑Yes ❑NO ❑N/A <br /> 25 the tank been tested as required by <br /> the designing engineer? <br /> Annual Checklist Page 3 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.