My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0002424 SSNL
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
N
>
NORTHLAND
>
6060
>
2600 - Land Use Program
>
UP-89-09
>
SU0002424 SSNL
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/2/2020 4:17:05 PM
Creation date
6/2/2020 3:56:29 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
FileName_PostFix
SSNL
RECORD_ID
SU0002424
PE
2626
FACILITY_NAME
UP-89-09
STREET_NUMBER
6060
Direction
E
STREET_NAME
NORTHLAND
City
MANTECA
ENTERED_DATE
10/26/2001 12:00:00 AM
SITE_LOCATION
6060 E NORTHLAND
QC Status
Approved
Scanner
SJGOV\gmartinez
标签
EHD - Public
该页面上没有批注。
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
52
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
k'■ KLEINFELDER <br /> File No.: 20-3121-02 <br /> November 2, 1988 <br /> Page 6 <br /> With these provisions, we recommend a maximum allowable bearing pressure of 2,000 <br />'3 pounds per square foot for dead plus live load be used in design. This value can be <br /> increased by one-third for the total of all loads, including wind or seismic forces. The <br /> recommended minimum width of foundations is 12 inches. The anticipated total <br /> settlement is less than 1/4-inch. The majority of this settlement should occur during <br /> construction as building loads are placed. <br /> Ii it is desired to use a higher bearing value, we recommend the structure be <br /> supported on a minimum of 2 feet of Engineered Fill beneath foundations. This will <br /> require overexcavation and recompaction of approximately 3 to 4 feet of the existing <br /> fill pad. With this provision, the recommended maximum bearing value can be <br /> • increased to 3,500 pounds per square foot for dead plus live load with a 1/3 increase <br /> for the total of all loads. With foundations supported entirely on Engineered Fill, <br />._ . settlement will be reduced. <br /> We recommend that the reinforcing design of the footings be provided by the <br /> structural engineer. We note that the above-stated bearing value is a net value and <br /> the weight of concrete in the portion of the foundations which extends below grade <br /> can be neglected in proportioning the foundations. <br /> It is recommended that all footing trenches on this project be observed by a <br />,., representative of our firm prior to placement of reinforcing steel. The purpose of <br /> T <br /> these observations is to verify that the bearing soils actually encountered in the <br /> j <br /> footing excavations are the same as those on which our recommendations are based, <br /> and to observe any loose pockets of soil or debris. <br /> 1 <br /> ,a <br /> a <br />
The URL can be used to link to this page
Your browser does not support the video tag.