Laserfiche WebLink
0 0 <br /> Pep Boys#711 <br /> (a)(5)(13)tank systems will be anchored to prevent flotation or dislodgement where the tank <br /> system is placed in a saturated zone,or is located within a seismic fault zone. See Table i,Figure <br /> 5 and photos in Appendix A. These restraints, together with the building wall are adequate to <br /> resist design earthquake forces calculated In accordance with the California Building Code.See <br /> calculations in Appendix E.Note that friction has not been included in the calculation of <br /> resistance to base shear force. The tank is not located in a saturated zone. <br /> (a)(5)(C)tank systems will withstand the effects of frost heave: Not applicable—the tank is at a <br /> low elevation in southern California. They are not subject to frost heave due to local climate <br /> conditions. <br /> (b)The owner or operator of a new tank system shall ensure that proper handling procedures <br /> are adhered to in order to prevent damage to the system during;installation.Prior to covering, <br /> enclosing,or placing a new tank system or component in use,an independent,qualified <br /> installation'inspector or an,independent,qualified,professional engineer,registered in <br /> California,either of whom is trained and experienced in the proper installation of tank systems, <br /> shall inspect the system or component for the presence of any of the following items: The <br /> inspection of the tank was conducted February 16,2012.See inspector's qualifications in <br /> Appendix D. <br /> (b)(1)Weld breaks:See ins ect orl results in Table IV. <br /> (b)(2)Punctures: See inspection results in Table IV.. <br /> (b)(3)Scrapes of protective coatings:See inspection results in Table 1V. <br /> (b)(4)Cracks:See inspection results In Table IV.' <br /> (b)(5)Corrosion:See inspection results in Table IV <br /> (b)(6)Other structural damage or inadequate construction or installation.All discrepancies shall <br /> be:eemedied before the tank system is covered,enclosed or placed in use.No discrepancies <br /> were noted. See inspection results in Table IV. <br /> (c}New tank systems or components and piping that are placed underground and that are <br /> backfilled shall be provided with a:backfill material that isa noncorrosive,porous,homogeneous <br /> substance and that is carefully installed so that the backfill is placed completely around the tank <br /> and compacted to ensure that the tank and piping are fully and uniformly supported.Not, <br /> applicable-the tank Is not underground. <br /> 6 <br />