Laserfiche WebLink
San Joa In Countv Environmental Health eDartment <br />EHD 22-02-004 Rev 7/06 600 E. MAIN ST., STOCKTON, CA 95202 (209) 468-3420 Paae 2 <br />Continued HAZARDOUS WASTE GENERATOR PROGRAM INSPECTION REPORT <br />Facility Address: <br />Ins ec'on D e: <br />Code Section VIOLATIONS <br />50 25160(d) HSC Transported hazardous waste without a manifest <br />51 25163(a) HSC Transported hazardous waste or transferred HW to a transporter without valid registration. <br />52 25160.2(c)(2) HSC Offered ineligible waste streams to be transported using consolidated manifest. <br />p <br />53 25160.2(b)(4) HSC Consolidated manifest receipts failed to contain complete information. <br />u, <br />54 25250.23 HSC Transported used oil and not registered as a hazardous waste hauler. <br />55 66263.17(a) CCR Transported hazardous waste without receiving ID Number and registration cert from DTSC. <br />56 66263.23(b) CCR Delivered hazardous waste to an unauthorized facility. <br />5 66265.17 CCR Failed to manage incompatible waste in containers properly. <br />58 66265.199 CCR Failed to manage incompatible waste in tanks properly. <br />59 25250.7 HSC Contaminated used oil with other hazardous waste. <br />60 66266.81(b) CCR Damaged lead acid batteries not properly managed and labeled. <br />61 66265.191(a) CCR Failed to determine if HW tank is leaking or unfit. <br />62 66265.191(b) CCR HW tank assessment not sufficient. <br />Y <br />63 66265.191(d) CCR If HW tank found leaking or unfit, failed to comply with 66265.196. <br />Z <br />64 66265.192 CCR Failed to retain on-site required certification for HW tanks. <br />65 66265.193 CCR Failed to provide secondary containment for HW tank. <br />Lu <br />1- <br />Q <br />66 66265.194(a) CCR Placed hazardous waste or reagents in tank system that caused the tank, containment <br />system or ancillary equipment to leak, corrode, rupture, or fail. <br />3 <br />67 66265.194(b) CCR Failed to use controls and practices to prevent spillage and overflows from tank system. <br />rn <br />M <br />68 66265.194(b)(3) CCR Failed to prevent overtopping from HW tank. <br />0 <br />69 66265195(a) CCR Failed to conduct dailv inspections of HW tank. <br />CCR Failed to inspect HW tank cathodic protection system. <br />W7066265.195(b) <br />71 66265.196 CCR Failed to immediately remove tank/secondary containment system that had leaked or spilled. <br />x <br />72 66265.197 CCR Tank closure, failed to remove/decon all waste and manage them as HW. <br />73 66265.198(a)/(b) CCR Failed to manage ignitable or reactive waste properly. <br />74 66265.199(a)/(b) CCR Failed to manage incompatible wastes properly. <br />Small Quantity Handler (SQH) did not manage UW according to these sections (a) -(c), [UW <br />75 66273.13 CCR Electronic Device (OWED) (d): Containment (1), Notification (2), SQ Handler Standards (3), <br />-Zoning(4), Residuals (5), M mt Standards (6), Treatment Standards (7).] <br />76 66273.14 CCR Small Quantity Handler did not mark universal waste according'to this section. <br />77_ 66273.15 CCR SQH had universal waste onsite for more than one year (a) or was unable to demonstrate the <br />lencith of time UW was accumulated from the date it became a waste or was received.(c) <br />Ujtu <br />N <br />78 66273.16 CCR SQH did not inform employees who handle UW proper handling and emergency procedures. <br />79 66273.32 CCR LQH did not notify the EPA RA to obtain an EPA ID #, [see UWED subsection (a)(3)(A)-(C)). <br />Q <br />80 66273.33 CCR Large Quantity Handler did not manage universal waste according to these sections (a) -(c) <br />Lu <br />81 66273.33(d) CCR Containment (1), Notification (2), LQ Handler Standards (3), Zoning (4), Residuals (5), Mgmt <br />Standards (6), Treatment Standards (7). <br />> <br />82 66273.34 CCR Large Quantity Handler did not label universal waste according to this section. <br />83 66273.35 CCR LQH had UW onsite for more than 1 year (a) or was unable to demonstrate the length of time <br />the UW has been accumulated from the date it became a waste or was received.(c) <br />84 66273.36 CCR LQH did not inform employees who handle UW proper handling and emergency procedures. <br />85 66273.39 CCR LQH did not keep records of each shipment of universal waste according to this section. <br />86 66273.82 CCR Cathode Ray Tube (CRT) handler accepts offsite'source failed to notify DTSC 30 days prior. <br />87 66273.83 CCR CRT Waste Management. <br />SQG's <br />(generates less than 1000 kg/mo) <br />88 66262.34(d) CCR & Stored hazardous waste onsite greater than 180 days <br />25123.3(h)(1) HSC <br />89 66262.34(d)(1) CCR Accumulated more than 6,000 kg onsite at one time. <br />90 66262.34(d)(2) CCR Modified emergency coordinator information lacking or insufficient [as referenced by CFR <br />262.34(d) and CFR (e)&(f).] <br />OTHER <br />91 66261.7(f) CCR <br />An empty HW or Haz Mat container (larger than 5 gallons) was not marked with the date it <br />was emptied/not managed within one year of being emptied. <br />92 25217.1 HSC <br />Liquid latex paint was disposed of, or attempted to be disposed of, to land or water. <br />93 See attached "Continuation -Official Inspection Report" for violations not listed above. <br />AhBPCC <br />94 1 1 1 25270-25270.13 HSC I Spill Prevention Control and .0cluntermeasure Plan not onsite for Petroleum AST's. <br />UIC I Septic System: _ Serves a 20 persons/day _ Receive�Recb' waste _ Dry wells/French Drains <br />EHD Inspector: <br />Title: <br />EHD 22-02-004 Rev 7/06 600 E. MAIN ST., STOCKTON, CA 95202 (209) 468-3420 Paae 2 <br />