My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WEST
>
4987
>
2200 - Hazardous Waste Program
>
PR0513935
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/9/2020 8:58:13 PM
Creation date
6/3/2020 9:21:17 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0513935
PE
2227
FACILITY_ID
FA0003969
FACILITY_NAME
PEP BOYS #711
STREET_NUMBER
4987
STREET_NAME
WEST
STREET_TYPE
LN
City
STOCKTON
Zip
95210
APN
10416027
CURRENT_STATUS
01
SITE_LOCATION
4987 WEST LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\HW\HW_2227_PR0513935_4987 WEST_.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
389
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ental Health Martment <br />San Joaquin Co a <br />Unified Hazardous Wash Generator Program <br />Address <br />Site Name <br />q► ' <br />VIOLATIONS <br />TANKS installed before 7/14/86) <br />Existing systems (' <br />a (CCR) Failed to determine if tank is leaking or unfit . <br />61 66265.1910 (CCR) Assessment not sufficient. <br />66265.191(b) ( 1 with 66265.19P.- <br />66265191 <br />6.___..____.._-- <br />62 CCR If found leaking or unfit, failed to comply <br />63 66265.191(d) (CCR) <br />New systems (installed after 7/14/86) required certification. <br />64 66265.192 (CCR) Failed to retain on-site req containment. <br />65 66265.193 (CCR) Failed to provide secondary reagents in tank system which caused the tank, containment <br />66 66265.194(a) (CCR) Placed hazardous waste or ptur <br />system or ancillary equipment to leak, corrode, rupture, or fail. <br />CR Failed to use controls and practices to prevent spillage and. overflows from tank system. <br />67 66265.194(b) () (CCR) Failed to prevent overtopping. <br />68 66265.194(b)(3) ( inspections. <br />69 66265.195(a) (CCR) Failed to conduct daily <br />66265.195(b) (CCR) Failed to inspect cathodic protection system. tem that had leaked or <br />70 remove tank s <br />(CCR) Failed to immediately ystem or secondary containments <br />Ys <br />71 66265.196 <br />spilled. n tank closure, failed to remove or decontaminated all waste residues, contaminated tank <br />72 66265.197 (CCR) During <br />system, soils, and manage them as hazardous waste. <br />73 <br />66265.198(a)and/or(b) (CCR) Failed to manage ignitable tible wastes properly. properly . <br />74 66265.199(a)and/or(b) (CCR) Failed to manage income <br />UNIVERSAL WASTE _ <br />all Quantity Handler did not mark or label the ruisito for smoregthas one year,'n this section. <br />as <br />75 66273.14 (CCCCR) <br />76, 66273.15(a) ( Small Quantity Handler had universal was <br />Small Quantity Handler was unable to demonstrate <br />to the length of time the universal was <br />tn and <br />77, 66273.15(c) (CCR) Smme a proper handling <br />been <br />accumulated from <br />QuantitytHandleradid not informemployeeswho handle universal waste <br />78, 66273.1 (CCR) <br />r e Quantity Handler did not notify the EPA Regional Administrator to obtain an EPA <br />ID <br />emergency procedures. <br />79, 66273.32 (CCR) Lag versal waste according to this section. <br />number.did not manage un <br />80, 66273.33 (CCR) Large Quantity Handler did not label universal waste accord ng to this section. <br />81, 66273.34 (CCR) Large Quantity Han <br />73.35 a) (CCR) <br />Large unable to demonstrate the length of time the universal waste has <br />83 6 <br />62 ( e Quantity Handler had universal waste onsite for more than one year. <br />83, 66273.35(b) (CCR) Large Quantity Handler wasproper handling <br />been accumulated from the date it became a waste or was received. <br />CCR Large Quantity Handler did not inform employees who. handle universal waste ste according to <br />84, 66273.36 (CCR) <br />Large <br />Quantity <br />and emergency p records of each shipment of universal waste <br />85. 66273.39 (CCR) Large Quantity Handler did not keep per calendar year <br />this section. (CRT) handler that accepts more than 5 CRT devices <br />86, notify DI <br />66273.82(b) (CCR) Cathode Ray Tube <br />SC and the CUPA according to section. <br />that genera to <br />per calendar year faile <br />from any offsite source failed to tes 5,000 kilograms or more of CRT ma <br />87, 66273.82(c) (CCR) CRT handler t g to this section. <br />to notify DTSC and the CUPA according <br />OTHERnot listed above. <br />88 <br />See attached "Continuation -Official Inspection Report" for violations) <br />SPCCround <br />5270.13 (HSC) Spill Prev tion Control and Countermea�e Plan on-site for aboveg <br />89 25270- 2 tank(s). � <br />petroleum storagePage of <br />0lb <br />EHS <br />Initialed by Dae <br />
The URL can be used to link to this page
Your browser does not support the video tag.