Laserfiche WebLink
Hazardous Waste Tank System December <br /> Preliminary Written Assessment per CCR Title 22 <br /> Chase Chevrolet quick Lube Stockton,CA 95212 2013 <br /> Tank Assessment Page Tank Waste Oil <br /> Tank age:8 years <br /> Manufacturer: Containment Solutions <br /> Remaining service life: 25 years, inspect <br /> in 5 years <br /> Tank Construction: <br /> Shape: Rectangular, Close top, with integral secondary containment <br /> Orientation: Horizontal <br /> Location (above/below ground): Above ground <br /> Material of construction: Steel, A36 <br /> Thickness and method Waste to determine: 0.15" by UTG <br /> Lining material & thickness (if applicable): N. A. <br /> Corrosion Protection equipment: Compatible <br /> Structural support: The tank rests on concrete foundation. <br /> Other identifying features: Red <br /> Piping and ancillary equipment (pumps): Qty 4, <br /> Piping Material of Construction: Steel/ Rubber Hose <br /> Piping Diameter: 1" <br /> Pump location(s): Within 40' of tank in Quick Lube Vault, above ground. <br /> Pump type(s)/capacities: Air Operated Diaphragm, 1" air operated <br /> diaphragm pump, 10 gpm, <br /> Overfill Protection: Audible alarm when tank reaches 90% of capacity. The <br /> system was tested and found to be operating. <br /> Material Storage: <br /> Material and characteristics: Waste motor oil, non-CRA Hazardous Waste, <br /> Class 111, B combustible liquid <br /> Specific Gravity: 0.95 <br /> Operating Capacity: 1,350 gallons1 <br /> RECEIVED <br /> A D <br /> I R 2 5 ?014 <br /> ENVIRONMENTAL <br /> HEALTH nFRSTMENT <br /> Strandberg Associates 1(866) 388-0404 rwaterguye. aterguy.ccim 2 <br />