Laserfiche WebLink
Hazardous Waste Tank System December <br /> Preliminary Written Assessment per CCR Title 22 <br /> Chase Chevrolet quack Lube Stockton,CA 95212 2013 <br /> Tank: Waste nitffr e <br /> Cylindrical, Vertical Closed Top, Fla# Bottom, Quble Walled <br /> Material of Construction: HDPE <br /> Shell Height, in 49.00 <br /> Shell Diameter, in 38.00 <br /> Working Volume, gal 216.00 <br /> S.G. of contents 1.05 <br /> Tank Wall Thickness, in 0.24 <br /> ' Total Weight of Tank and Contents, lbs 1961.00 <br /> Zip Code 95212 <br /> Overturning Moment Arm, in 24.00 <br /> Resisting Moment Arm, in 19.00 <br /> Sds 0.60 <br /> Importance Factor 1.00 <br /> Fp, ASCE 7-05, 15.4-2 352.98 <br /> Overturning Moment inlbf 8471.52 <br /> Resisting Moment, inlbf 37259.00 <br /> Overturning Safety Factor - No Tension 4.40 <br /> Shear Strength of Anchor. Lbs 2320.00 <br /> of Anchors 0.00 <br /> Factor of Safety for Shear 0.00 <br /> ' Seismic/Anchoring findings: The tank as designed eAd operated and the <br /> containment area in which it is located are adequat y nchored and are <br /> seismically sound. Initials: <br /> RECEIVED <br /> APP 2 5 7-014 <br /> ENVIRONMENTAL <br /> HEAUM F <br /> Strandberg Associates 1{666} 388-0404 rwater uy(a)rwaterguy corn 21 <br />