Laserfiche WebLink
Hazardous Waste Tank System <br />Preliminary Written Assessment per CCR Title 22 <br />Chase Chevrolet quick Lube Stockton, CA 95212 <br />Volume calculation(s) <br />E <br />WIN <br />The waste oil tank has integral secondary containment. <br />Both the waste oil tank and waste antifreeze tank are within the Quick Lube <br />service vault which provides secondary containment for tanks, pumps and piping. <br />The vault's volume is 48' x 28' x 75 = 10,080 M which equals 75,398, gallons. <br />The largest tank is 1,500 gallons. The secondary containment is sufficient. <br />Visual inspection of containment area <br />Inspection of the service vault found it free of <br />damage. The concrete is painted with epoxy I <br />impermeable. <br />Site Security: The waste oil and <br />The area has a security systema <br />routinely patrolled by the Stockt6l <br />Ppalling, gaps or other <br />ch makes it reasonable <br />tanks are within locked areas. <br />when not attended. The area is <br />Secondary Containment findings: The secondary containment system is of <br />sufficient capacity and condition for the containment of releases from all tanks <br />and ancillary equipment. Initials: <br />Strandberg Associates 1(866) 388-0404 Er)water y <br />A�q _Qr� �ter 28 <br />