My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
A
>
AIRPORT
>
5151
>
2200 - Hazardous Waste Program
>
PR0537529
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/10/2020 10:11:34 AM
Creation date
6/3/2020 9:23:26 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0537529
PE
2229
FACILITY_ID
FA0014894
FACILITY_NAME
SIMPSON STRONG-TIE CO
STREET_NUMBER
5151
Direction
S
STREET_NAME
AIRPORT
STREET_TYPE
Way
City
Stockton
Zip
95206
APN
17746023
CURRENT_STATUS
01
SITE_LOCATION
5151 S Airport Way
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\HW\HW_2229_PR0537529_5151 S AIRPORT_.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
317
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CERS Consolidated Emergency Response/ ntingency Plan <br /> INTERNAL FACILITY EMERGENCY COMMUNICATIONS OR ALARM NOTIFICATION WILL OCCUR BY(Check all that apply): cit. <br /> ❑ 1.VERBAL WARNINGS, M 2.PUBLIC ADDRESS OR INTERCOM SYSTEM; ❑3.TELEPHONE; <br /> ❑4.PAGERS; 5.ALARM SYSTEM; 6.PORTABLE RADIO <br /> NOTIFICATIONS TO NEIGHBORING FACILITIES THAT MAY BE AFFECTED BY AN OFF-SITE RELEASE WILL OCCUR BY(Check all that apply): Cie. <br /> ❑ 1.VERBAL WARNINGS; ❑2.PUBLIC ADDRESS OR INTERCOM SYSTEM; 0 3.TELEPHONE, <br /> ❑4.PAGERS; [:15.ALARM SYSTEM; ❑6.PORTABLE RADIO <br /> EMERGENCY COORDINATOR CONTACT INFORMATION: David Olney C13. <br /> PRIMARY EMERGENCY COORDINATOR NAME: David Olney PHONE NO.: (209) 941-1145 PHONE NO.: <br /> ALTERNATE EMERGENCY COORDINATOR NAME: Tony Cervantez PHONE NO.: (510) 715-7448 PHONE NO.: <br /> ❑Check if additional Emergency Coordinator contact and address information is available onsite or by calling PHONE NO.: <br /> Note:If more than one alternate emergency coordinator is designated,attach a list in order of responsibility. <br /> D. EMERGENCY CONTAINMENT AND CLEANUP PROCEDURES <br /> Check the applicable boxes to indicate your facility's procedures for containing spills and preventing and mitigating releases,fires and/or explosions. <br /> Dt. <br /> Fal 1. MONITOR FOR LEAKS,RUPTURES,PRESSURE BUILD-UP,ETC.; <br /> 0 2. PROVIDE STRUCTURAL PHYSICAL BARRIERS(e.g.,Portable spill containment walls,built-in berms); <br /> 0 3. PROVIDE ABSORBENT PHYSICAL BARRIERS(e.g.,Pads,spill pigs,spill pillows), <br /> 0 4. COVER OR BLOCK FLOOR AND/OR STORM DRAINS; <br /> ❑5. LINED TRENCH DRAINS AND/OR SUMPS; <br /> 0 6. AUTOMATIC FIRE SUPPRESSION SYSTEM; <br /> 0 7. ELIMINATE SOURCES OF IGNITION FOR FLAMMABLE HAZARDS; <br /> E 8. STOP PROCESSES AND/OR OPERATIONS; <br /> 0 9. AUTOMATIC/ELECTRONIC EQUIPMENT SHUT-OFF SYSTEM; <br /> 0 10.SHUT OFF WATER,GAS,ELECTRICAL UTILITIES; <br /> 0 11.CALL 9-1-1 FOR PUBLIC EMERGENCY RESPONDER ASSISTANCE AND/OR MEDICAL AID; <br /> R 12.NOTIFY AND EVACUATE PERSONS IN ALL THREATENED AND/OR IMPACTED AREAS; <br /> 13.ACCOUNT FOR EVACUATED PERSONS IMMEDIATELY AFTER EVACUATION; <br /> Q 14.PROVIDE PROTECTIVE EQUIPMENT FOR ON-SITE EMERGENCY RESPONSE TEAM, <br /> Pol 15.REMOVE CONTAINERS AND/OR ISOLATE AREAS; <br /> R 16.HIRE LICENSED HAZARDOUS WASTE CONTRACTOR; <br /> 0 IT USE ABSORBENT MATERIAL FOR SPILL CONTAINMENT; <br /> ❑ 18.VACUUM SUCTION USING APPROPRIATE VACUUM(e.g.,Intrinsically safe)FOR SPILL CONTROL AND/OR CLEANUP; <br /> R 19.DECONTAMINATE PERSONNEL AND EQUIPMENT WITHIN DESIGNATED AREA AND DISPOSE OF WASTEWATER AS HAZARDOUS WASTE; <br /> 20.PROVIDE SAFE TEMPORARY STORAGE OF HAZARDOUS WASTE GENERATED DURING EMERGENCY ACTIONS; <br /> S eci oz. <br /> 21.OTHER <br /> (Specify): Contacting our vendor Safety Kleen in the event of a larger spill <br /> E. FACILITY EVACUATION <br /> THE FOLLOWING ALARM SIGNAL(S)WILL BE USED TO BEGIN EVACUATION OF THE FACILITY(Check all that apply): El. <br /> ❑ 1. BELLS; E2 <br /> E 2. HORNS/SIRENS; <br /> 0 3. VERBAL(i.e.,Shouting); <br /> [j]4. OTHER(Specify): Internal reporting process using portable radios <br /> THE FOLLOWING LOCATION(S)WILL BE USED FOR AN EMERGENCY ASSEMBLY AREA(S)(e.g.,Parking lot,street comer): E3. <br /> Farthest point from the structure in parking lots indicating"emergency assembly area"signs red with white lettering <br /> Note:The Emergency Coordinator must account for all onsite employees and visitors after evacuation. <br /> EVACUATION ROUTE S AND ALTERNATE EVACUATION ROUTES ARE DESCRIBED AS FOLLOWS: E4. <br /> Q 1.WRITTEN PROCEDURES DESCRIBING ROUTES,EXITS,AND ASSEMBLY AREAS; <br /> 2.EVACUATION MAP(S)DEPICTING ROUTES,EXITS,AND ASSEMBLY AREAS; <br /> ❑3. OTHER(Specify): E5. <br /> Note:Evacuation procedures and/or maps should be posted in visible facility locations and must be included in the Contingency Plan. <br /> F. ARRANGEMENTS FOR EMERGENCY SERVICES <br /> ADVANCE ARRANGEMENTS FOR LOCAL EMERGENCY SERVICES(Check one of the following): Fl. <br /> ❑ 1. HAVE BEEN DETERMINED NOT NECESSARY; <br /> 0 2. THE FOLLOWING ARRANGEMENTS HAVE BEEN MADE(Specify): We have discussed our plan at length with the Stockton Fire Dept which F2. <br /> they have had input and agreed upon for emergency response services <br /> Note:Advance arrangements with local fire and police departments,hospitals,state and local emergency response teams,and/or emergency services <br /> contractors should be made for your facility,if necessary. Large Quantity Generators must describe arrangements in the Contingency Plan. <br /> Rev.03/07/17 Page 2 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.