My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1989-1990
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
R
>
ROTH
>
850
>
2300 - Underground Storage Tank Program
>
PR0231898
>
COMPLIANCE INFO_1989-1990
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/10/2020 2:39:04 AM
Creation date
6/3/2020 9:42:50 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1989-1990
RECORD_ID
PR0231898
PE
2332
FACILITY_ID
FA0003966
FACILITY_NAME
SHARPE SITE/DEF LOG AGENCY
STREET_NUMBER
850
Direction
E
STREET_NAME
ROTH
STREET_TYPE
RD
City
LATHROP
Zip
95330
APN
19802001
CURRENT_STATUS
02
SITE_LOCATION
850 E ROTH RD
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2332_PR0231898_850 E ROTH_1989-1990.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
405
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CALIFORNS WATER RESOURCES CONTFBOARD <br /> LF'^la�o rM1F. <br /> FORM V: UN D GROUND STORAGE TANK PROGRAM o <br /> TANK TANK PERMIT APPLICATION INFORMATION <br /> COMPLETE A SEPARATE FORM WITH THE FOLLOWING INFORMATION FOR EACH TANK. e. <br /> MARK ONLY ❑ 1 NEW PERMIT ❑3 RENEWAL PERMIT ❑5 CHANGE OF INFORMATION ❑ PERMANENTLY CLOSED TANK <br /> ONE ITEM ❑2 INTERIM PERMIT F-]4 AMENDED PERMIT ❑6 TEMPORARY TANK CLOSURE TANK REMOVED 06( <br /> FACILITY/SITE NAME WHERE TANK IS INSTALLED: FARM TANK-YES❑ NO Q <br /> • <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS-IF UNKNOWN—SO SPECIFY <br /> A. OWNERS TANK ID If B. MANUFACTURED BY: <br /> C. YEAR INSTALLED D. TANK CAPACITY IN GALLONS: 0`0 <br /> E 0* <br /> II. TANK CONTENTS IF(A.1),IS MARKED,COMPLETE ITEM C.IF(A.1),IS NOT MARKED,COMPLETE ITEM D. Q <br /> A. ❑ 1 MOTOR VEHICLE FUEL ❑ 2 PETROLEUM C. ❑ 1 UNLEADED ❑ 2 LEADED EA"3 DIESEL <br /> ❑ 3 CHEMICAL PRODUCT ❑4 OIL 1 PRODUCT 4 GASAHOL ❑ 5 JET FUEL ❑6 AVIATION GAS <br /> ❑ 5 HAZARDOUS ❑80 EMPTY ❑ 95 UNKNOWN ❑2 WASTE ❑ 7 METHANOL ❑ 99 OTHER(DESCRIBE IN ITEM D,BELOW) <br /> D. IF NOT MOTOR VEHICLE FUEL,ENTER NAME OF <br /> HAZARDOUS SUBSTANCE STORED&C.A.S.# C.A.S.#: <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOX A,B,C,&D <br /> A.TYPE OF ❑kr2 <br /> LISLE WALLED F-13 SINGLE WALLED WITH EXTERIOR LINER ❑95 UNKNOWN <br /> SYSTEM GLE WALLED ❑4 SECONDARY CONTAINMENT ❑99 OTHER <br /> F-1i STEEL/IRON ❑2 STAINLESS STEEL F-] 3 FIBERGLASS ❑ 4 STEEL CLADW/FIBERGLASS REINFORCED PLASTIC <br /> B.TANK <br /> MATERIAL F-15 CONCRETE ❑6 POLYVINYLCHLORIDE F-] 7 ALUMINUM ❑ 8 100%METHANOL COMPATIBLE FRP <br /> ❑9 BRONZE ❑ 10 GALVANIZED STEEL ❑ 95 UNKNOWN ❑ 99 OTHER <br /> ❑ <br /> C. INTERIOR 1 RUBBER LINED F-12 ALKYD LINING F-13 EPDXY LINING ❑4 PHENOLIC LINING <br /> LINING ❑5 GLASS LINING ❑6 UNLINED ❑95 UNKNOWN <br /> ❑ IS LINING MATERIAL COMPATIBLE WITH 100%METHANOL? ❑YES ❑ NO ❑ 99 OTHER <br /> D.CORROSION ❑ 1 POLYETHLENE WRAP ❑2 TAR OR ASPHALT ❑ 3 VINYL WRAP ❑ 4 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION ❑5 CATHODIC PROTECTION ❑91 NONE ❑ 95 UNKNOWN ❑ 99 OTHER <br /> IV. PIPING INFORMATION CIRCLE A IF ABOVE GROUND, U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A.SYSTEM TYPE A U 1 SUCTION A U 2 PRESSURE A U 3 GRAVITY A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> B.CONSTRUCTION A U 1 SINGLE WALLED A U 2 DOUBLE WALLED A U 3 LINED TRENCH A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> A U 1 STEEL/IRON A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC) A U 4 FIBERGLASS PIPE A U,91 NONE <br /> C.MATERIAL A U 5 ALUMINUM A U 6 CONCRETE A U 7 STEEL CLAD W/FRP A U 8 100%METHANOL COMPATIBLE FRP <br /> A U 9 GALVANIZED STEEL A U 95 UNKNOWN A U 99 OTHER <br /> V. LEAK DETECTION SYSTEM CIRCLE P FOR PRIMARY,OR S FOR SECONDARY,A PRIMARY LEAK DETECTION SYSTEM MUST BE CIRCLED. <br /> P S 1 VISUAL CHECK P S 2 INVENTORY RECONCILIATION P S 3 VADOSE WELLS P S 4 ELECTRONIC MONITOR P S 5 GROUND WATER MONITORING WELLS <br /> P S 6 PRECISION TESTING P S 7 PRESSURE TESTING P S 91 NONE P S 95 UNKNOWN P S 99 OTHER <br /> VI. INFORMATION ON TANK PERMANENTLY CLOSED IN PLACE <br /> 1. ESTIMATED DATE LAST USED(MO/YR) 2. ESTIMATED QUANTITY OF 3.WAS TANK FILLED WITH <br /> SUBSTANCE REMAINING IN GALLONS INERT MATERIAL? ❑YES [:] NO <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE,IS TRUE AND CORRECT. <br /> APPLICANT'S NAME(PRINTED&SIGNATURE) DATE <br /> LOCAL AGENCY USE ONLY <br /> COUNTY# JURISDICTION# AGENCY# FACILITY ID# TANK ID# <br /> E�� I- I I I = 1 1 LLI / Ig- l ; lirl [ I- <br /> 11 A <br /> CURRENT LOCAL AGENCY FACILITY ID# APPROVED BY NAME PHONE#WITH AREA CODE <br /> 0 <br /> PERMIT NUMBER PERMIT APPROVAL DATE PERMIT EXPIFIIATIOA DATE <br /> CHECK# PERMIT AMOUNT SU HARGE AMT. FEE CODE REC T# BY:C <br /> CHECK# T� LL <br /> FORM B(6-29-88) THIS FORM MUST BE ACCOMPANIED BY A FACILITY/SITE APPLICATION, FORM 'A',UNLESS A CURRENT FORM`A' HAS BEEN FILED <br /> DATA PROCESSING COPY <br />
The URL can be used to link to this page
Your browser does not support the video tag.