Laserfiche WebLink
W <br />KLEINFELDER <br />MOISTURE DENSITY ANALYSES <br />ASTM D-1557 <br />Method <br />Material Description and Source <br />Maximum <br />Dry Density <br />Optimum <br />Moisture Content <br />Curve <br />Number <br />C <br />Aggregate Base/import <br />139.7 pcf <br />5.0% <br />1** <br />** Previously reported, File No. 20-00419X <br />OR I I q � !i '111 1 111 � I JIM N R <br />Test <br />No. <br />Date <br />2001 <br />Test Location <br />Depth From <br />Finished <br />Su rade fr. <br />Moisture <br />%Dry <br />Wel hIf <br />Dry <br />Density <br />I P.C.F. <br />Laboratory <br />Compaction <br />Curve No. <br />Relative <br />Compaction <br />SFeciTred <br />Relative <br />Compaction <br />BUILDING PAD <br />1 <br />06/14 <br />South side <br />FAB <br />4.1 <br />132 <br />1 <br />95 <br />95 <br />2 <br />06/14 <br />Center <br />FAB <br />5.2 <br />134 <br />1 <br />96- <br />95 <br />3 <br />06/14 <br />North side <br />FAB <br />4.7 <br />133 <br />1 <br />95 <br />95 <br />C <br />20-0121-01/2011 R1031 Pae 1 of 1 August 30 2001 <br />Accepted engineering and testing procedures were used for these tests. The above data is presented for information purposes only. in the absence of continuous observations of our personnel at the site, we cannot express <br />an opinion as to the adequacy of site preparation or overall fill compaction. We do not undertake the guarantee of construction, nor do we relieve the contractor of his primary responsibility to produce a completed project <br />conforming to the project plans and specifications. Copyright 2001 Kleinfelder, Inc. <br />