Laserfiche WebLink
�••18to� O a. <br />ep Rces <br />STATE OF CALIFORNIA `•'�, <br />STATE WATER RESOURCES CONTROL BOARDAba <br />UNDERGROUND STORAGE TANK PERMIT APPLICATION - FORM Bio <br />,�, <br />• C�[IFpP N.r <br />COMPLETE A SEPARATE FORM FOR !2 TANK SYSTEM. <br />MARK ONLY ❑ 1 NEW PERMIT 0 3 RENEWAL PERMIT 5 CHANGE OF INFORMATION ❑ 7 PERMANENTLY CLOS''� SITE <br />ONE ITEM ❑ 2 INTERIM PERMIT ❑ 4 AMENDED PERMIT ❑ 6 TEMPORARY TANK CLOSURE ❑ 8 TANK REMOVED ( / / J t <br />DBA OR FACILITY NAME WHERE TANK IS INSTALLED: S k p <br />I. TANK DESCRIPTION COMPLETE ALL ITEMS -- SPECIFY IF UNKNOWN �7 <br />A. OWNER'S TANK 1. D. # <br />B. <br />B. MANUFACTURED BY: <br />C. DATE INSTALLED (MO/DAY/YEAR) <br />k <br />D. TANK CAPACITY IN GALLONS: <br />IL TANKCONTFNTS IFA-1I.SMARKFD COMPLETE ITEM C. y % <br />A ❑ 1 MOTOR VEHICLE FUEL ❑ 4 OIL <br />B. <br />to REGULAR 3 DIESEL ❑ 6 AVIATION GAS <br />C• ❑ <br />❑ 95 UNKNOWN <br />SYSTEM <br />UNLEADED <br />4 GASAHOL <br />PETROLEUM ❑ 80 EMPTY <br />1 PRODUCT <br />❑ lb PREMIUM ❑ 7 METHANOL <br />UNLEADED 0 JET L <br />❑ 3 CHEMICALPRODUCT E:]95 UNKNOWN <br />2 WASTE <br />0 <br />❑ 2 LEADED 99OTHER(DESCRIBE IN ITEM D. BELOW) <br />❑ <br />D. IF (A.1) IS NOT MARKED, ENTER NAME OF SUBSTANCE STORED C. A. S. #: <br />III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOXES A. 8. AND C_ AND ALL THAT APPI IFS IN ROX D AND F <br />A. TYPE OF <br />Eol'i DOUBLE WALL <br />❑ 3 SINGLE WALL WITH EXTERIOR LINER <br />❑ 95 UNKNOWN <br />SYSTEM <br />❑ 2 SINGLE WALL <br />❑ 4 SECONDARY CONTAINMENT (VAULTEDTANK) <br />❑ 99 OTHER <br />A U <br />❑ 1 BARE STEEL <br />❑ 2 STAINLESS STEEL <br />❑ 3 FIBERGLASS <br />❑ 4 STEEL CLAD W/ FIBERGLASS REINFORCED PLASTIC <br />B. TANK <br />MATERIAL <br />❑ 5 CONCRETE <br />❑ 6 POLYVINYL CHLORIDE <br />❑�INUM <br />❑ 8 100% METHANOL COMPATIBLE W/FRP <br />(PrimaryTank) <br />❑ 9 BRONZE <br />❑ 10 GALVANIZED STEEL <br />95 UNKNOWN <br />❑ 99 OTHER <br />A U <br />❑ 1 RUBBER LINED <br />❑ 2 ALKYD LINING <br />XY LINING <br />❑ 4 PHENOLIC LINING <br />C. INTERIOR <br />LINING <br />E-15 GLASS LINING <br />F--]6 UNLINED <br />95 UNKNOWN <br />❑ 99 OTHER <br />A U <br />IS LINING MATERIAL COMPATIBLE WITH 100% METHANOL? <br />YES_ NO— <br />A U <br />D. CORROSION <br />❑ 1 POLYETHYLENE WRAP <br />❑ 2 COATING <br />❑3 YL WRAP <br />❑ 4 FIBERGLASS REINFORCED PLASTIC <br />PROTECTION <br />❑ 5 CATHODIC PROTECTION <br />❑ 91 NONE <br />95 UNKNOWN <br />❑ 99 OTHER <br />E. SPILL AND OVERFILL SPILL CONTAINMENT INSTALLED (YEAR) <br />OVERFILL PREVENTION EQUIPMENT INSTALLED (YEAR) <br />IV. PIPING INFORMATION CIRCLE A IFABOVEGFIOUNDOR U IF UNDERGROUND. BOTH IFAPPLICABLE <br />A. SYSTEM TYPE <br />A n <br />1 SUCTION <br />A U <br />2 PRESSURE A U <br />3 GRAVITY <br />A U 99 OTHER <br />B. CONSTRUCTION <br />A U <br />1 SINGLE WALL <br />A U <br />2 DOUBLE WALL A U <br />3 LINED TRENCH <br />A U 95 UNKNOWN <br />A U 99 OTHER <br />C. MATERIAL AND <br />A U <br />1 BARE STEEL <br />A U <br />2 STAINLESS STEEL A U <br />3 POLYVINYL CHLORIDE (PVC) A U <br />4 FIBERGLASS PIPE <br />CORROSION <br />A U <br />5 ALUMINUM <br />A U <br />6 CONCRETE A U <br />7 STEEL W/COATING <br />A U <br />8 100°/ METHANOL COMPATIBLE W/FRP <br />PROTECTION <br />A U <br />9 GALVANIZED STEEL <br />A U <br />10 CATHODIC PROTECTION <br />A&)95 UNKNOW <br />A U <br />99 OTHER <br />D. LEAK DETECTION <br />[:]1 <br />AUTOMATIC LINE LEAK <br />DETECTOR <br />3 <br />❑ 2 LINE TIGHTNESS TESTING 10 <br />INfERSTITIAL <br />❑ 99 OTHER <br />MONrroRING <br />V. TANK LEAK DETECTION <br />❑ 1 VISUAL CHECK ❑ 2 INVENTORY RECONCILIATION ❑ 3 VADOZE MONITORING ❑ 4 AUTOMATIC TANK GAUGING ❑ 5 GROUND WATER MONITORING <br />❑ 6 TANK TESTING ❑ 7 INTERSTITIAL MONITORING ❑ 91 NONE ❑ 95 UNKNOWN ❑ 99 OTHER <br />VI. TANK CLOSURE INFORMATION <br />1. ESTIMATED DATE LAST USED (MO/DAY/YR) 2. ESTIMATED QUANTITY OF 3. WAS TANK FILLED WITH YES 0 NO ❑ <br />SUBSTANCE REMAINING GALLONS INERT MATERIAL 7 <br />THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY, AND TO THE BEST OF MY KNOWLEDGE, 1S TRUE AND CORRECT <br />APPLICANTS NAME DATE <br />(PRINTED 8 SIGNATURE) <br />LOCAL AGENCY USE ONLY THE STATE I.D. NUMBER IS COMPOSED OF THE FOUR NUMBERS BELOW <br />COUNTY # JURISDICTION # FACILITY # 9 (pyo TANK # <br />STATE I.D.# ®—� g <br />n� <br />PERMIT NUMBER PERMIT APPROVED BY/DATE PERMIT EXPIRATION DATE <br />THIS FORM MUST BE ACCOMPANIED BY A PERMIT APPLICATION - FORM A. UNLESS A CURRENT FORM A HAS BEEN FILED. <br />FILE THIS FORM WITH TfpCAL AGENCY IMPLEMENTING THE UNDERGROUND STWE TANK REGULATIONS <br />FORM B (12-91) FQROQ348-4 <br />