Laserfiche WebLink
STATE OF CALIFORNIA • �?' �° <br /> STATE WATER RESOURCES CONTROL BOARD <br /> UNDERGROUND STORAGE TANK PERMIT APPLICATION- FORM B <br /> COMPLETE A SEPARATE FORM FOR EACH TANK SYSTEM. <br /> 7524-35 <br /> MARK ONLY ❑ 1 NEW PERMIT ❑ 3 RENEWAL PERMIT5 CHANGE OF INFORMATION ❑ 7 PERMANENTLY CLOSED.- ITE <br /> ONE ITEM F-] 2 INTERIM PERMIT F-14 AMENDED PERMIT In 6 TEMPORARY TANK CLOSURE 8 TANK REMOVED <br /> DBA OR FACILITY NAME WHERE TANK IS INSTALLED: <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS-- SPECIFY IF UNKNOWN <br /> A. OWNER'S TANK I.D.# 7524-35-RU-2 B. MANUFACTURED BY: RHEEM <br /> C. DATE INSTALLED(MO/DAYNEAR) 1967 D. T"NK CAPACITY IN GALLONS: 5 000 <br /> ILTANKCONTENTS IFA-1 IS MARKED,COMPLETE ITEM C. <br /> IM 1 MOTOR VEHICLE FUEL ❑ 4 OIL g, C � 1a REGULAR 3 DIESEL <br /> A. UNLEADED ❑ 6 AVIATION GAS <br /> 2 PETROLEUM BO EMPTY 1 PRODUCT 1b PREMIUM 4 GASAHOL 7 METHANOL <br /> UNLEADED 5 JET FUEL <br /> 3 CHEMICAL PRODUCT ❑ 95 UNKNOWN 2 WASTE ❑ ❑ <br /> 2 LEADED � gg OTHER (DESCRIBE IN ITEM D. BELOW) <br /> D. IF(A.1)IS NOT MARKED, ENTER NAME OF SUBSTANCE STORED C.A.S.#: <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOXES A,B,AND C,AND ALL THAT APPLIES IN BOX D AND E <br /> A. TYPE OF ❑ 1 DOUBLE WALL F-� 3 SINGLE WALL WITH EXTERIOR LINER 95 UNKNOWN <br /> SYSTEM 2 SINGLE WALL ❑ 4 SECONDARY CONTAINMENT (VAULTED TANK) ❑ 99 OTHER <br /> B. TANK1 BARE STEEL F-] 2 STAINLESS STEEL 3 FIBERGLASS 4 STEEL CLAD W/FIBERGLASS REINFORCED PLASTIC <br /> MATERIAL ❑ 5 CONCRETE F-1 6 POLYVINYL CHLORIDE 7 ALUMINUM a 8 100% METHANOL COMPATIBLE W/FRP <br /> (PrimaryTank) E::] 9 BRONZE Ej 10 GALVANIZED STEEL 95 UNKNOWN 99 OTHER <br /> F-] 1 RUBBER LINED F-� 2 ALKYD LINING F-1 3 EPDXY LINING Q 4 PHENOLIC LINING <br /> C.INTERIOR F--] 5 GLASS LINING 6 UNLINED 95 UNKNOWN 99 OTHER <br /> LINING ki <br /> IS LINING MATERIAL COMPATIBLE WITH 100% METHANOL? YES NO <br /> D.CORROSION ❑ 1 POLYETHYLENE WRAP F-] 2 COATING O 3 VINYL WRAP 4 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION ❑ 5 CATHODIC PROTECTION ❑ 91 NONE 95 UNKNOWN a 99 OTHER <br /> E.SPILL AND OVERFILL SPILL CONTAINMENT INSTALLED(YEAR) OVERFILL PREVENTION EQUIPMENT INSTALLED(YEAR) <br /> IV.PIPING INFORMATION CIRCLEA IF ABOVE GROUND OR U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A. SYSTEM TYPE A U 1 SUCTION AA& 2 PRESSURE A U 3 GRAVITY A U 99 OTHER <br /> B. CONSTRUCTION Ato 1 SINGLE WALL A U 2 DOUBLE WALL A U 3 LINED TRENCH A U 95 UNKNOWN A U 99 OTHER <br /> C. MATERIAL AND A U 1 BARE STEEL A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC)kiflFIBERGLASS PIPE <br /> CORROSION A U 5 ALUMINUM A U 6 CONCRETE A U 7 STEEL W/COATING A U 8 100% METHANOL COMPATIBLE W/FRP <br /> PROTECTION A U 9 GALVANIZED STEEL A U 10 CATHODIC PROTECTION A U 95 UNKNOWN A U 99 OTHER <br /> D. LEAK DETECTION J6 1 AUTOMATIC LINE LEAK DETECTOR 2 LINE TIGHTNESS TESTING ❑ 3 MOTERSTITIAL <br /> NITORING ❑ 99 OTHER <br /> V.TANK LEAK DETECTION <br /> ❑ 1 VISUAL CHECK�NVENTORY RECONCILIATION 3 VADOZE MONITORI �p TAPI6C0ftftpQ❑ 5 GROUND WATER MONITORING <br /> 6 TANK TESTING 7 INTERSTITIAL MONITORING ❑ 91 NONE 95 UNKNOWN 99 OTHER <br /> VI.TANK CLOSURE INFORMATION <br /> 1.ESTIMATED DATE LAST USED(MO/DAYNR) 2.ESTIMATED QUANTITY OF 3.WAS TANK FILLED WITH YES ❑ NO ❑ <br /> SUBSTANCE REMAINING GALLONS INERT MATERIAL? <br /> THIS FORM HAS BEEN COMPL,P70 UNDE AL N OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE, IS RU AND CORRECT <br /> APPLICANTS NAME� DATA '� <br /> (PRINTED 8 SIGNATURE) `- /J <br /> LOCAL AGENCY USE ONLY TOE STATE I.D.NUMBER IS COMPOSED OF THE FOUR NUMBERS BELOW <br /> COUNTY# JURISDICTION# FACILITY# TANK# <br /> VO <br /> STATE LD.# LZE7 <br /> ❑m <br /> PERMIT NUMBER PERMIT APPROVED BY/DATE PERMIT EXPIRATION DATEtv <br /> FORM B (7-91) THIS FORM MUST BE ACCOMPANIED BY A PERMIT APPLICATION-FORM A,UNLESS A CURRENT FORM A HAS BEEN FI <br /> FOR003 11.RS <br />