My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1995-2004
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
COUNTRY CLUB
>
2575
>
2300 - Underground Storage Tank Program
>
PR0231070
>
COMPLIANCE INFO_1995-2004
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/30/2023 2:09:10 PM
Creation date
6/3/2020 9:43:33 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1995-2004
RECORD_ID
PR0231070
PE
2351
FACILITY_ID
FA0006439
FACILITY_NAME
COUNTRY CLUB MOBIL CIRCLE K
STREET_NUMBER
2575
STREET_NAME
COUNTRY CLUB
STREET_TYPE
BLVD
City
STOCKTON
Zip
95204
CURRENT_STATUS
01
SITE_LOCATION
2575 COUNTRY CLUB BLVD
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2351_PR0231070_2575 COUNTRY CLUB_1995-2004.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
431
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
16 OIFIED PROGRAM CONSOLIDATED FOR <br /> \ ` )TANKS <br /> UNDERGROUND <br /> UNDERGROUND STORAGE TANKS - TANK PAGE 2 <br /> . 7 <br /> VI.,PIPING,CONSTRUCTION(CheCkelithat apply) <br /> )ERGROUND PIPING ABOVEGROUND PIPING <br /> -Y STEM TYPE X 1. PRESSURE F 2. SUCTION r 3. GRAVITY r 1. PRESSURE r 2. SUCTION r 3. GRAVITY 459 <br /> CONSTRUCTION r 1. SINGLE WALL r 3. LINED TRENCH r 99. OTHER r 1. SINGLE WALL r 95. UNKNOWN 462 <br /> / X 2. DOUBLE WALL r 95. UNKNOWN r 2. DOUBLE WALL r 99. OTHER <br /> MANUFACTURE <br /> R MANUFACTURER 461 MANUFACTURER 463 <br /> I 1.BARE STEEL r 6. FRP COMPATIBLE W/100%METHANOL F 1. BARE STEEL F 6. FRP COMPATIBLE W/100%METHANOL <br /> [MATERIALS AND 12. STAINLESS STEEL r 7. GALVANIZED STEEL r 2. STAINLESS STEEL r 7. GALVANIZED STEEL <br /> CORROSION r <br /> PROTECTION 3. PLASTIC COMPATIBLE WITH CONTENTS r 95. UNKNOWN r 3. PLASTIC COMPATIBLE WITH CONTENTS r 8. FLEXIBLE(HDPE) r 99. OTHER <br /> X 4. FIBERGLASS r B. FLEXIBLE(HDPE) IF 99. OTHER r 4. FIBERGLASS r 9. CATHODIC PROTECTION <br /> r 5. STEEL W/COATING F 9. CATHODIC PROTECTION 4641 r 5. STEEL W/COATING I 95. UNKNOWN 465 <br /> VII.PIPING LEAK DETECTION(Check all that apply)(A dascrtpBon of the monitoring program.ahall be submitted to;the k)qa/agency:) <br /> UNDERGROUND PIPING ABOVEGROUND PIPING <br /> SINGLE WALL PIPING 466 SINGLE WALL PIPING 467 <br /> PRESSURIZED PIPING(Check all that apply): PRESSURIZED PIPING(Check all that apply): <br /> F 1. ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP SHUT OFF FOR r 1.ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP SHUT OFF FOR LEAK, <br /> LEAK SYSTEM FAILURE,AND SYSTEM DISCONNECTION+AUDIBLE AND VISUAL SYSTEM FAILURE,AND SYSTEM DISCONNECTION+AUDIBLE AND VISUAL ALARMS <br /> ALARMS I 2. MONTHLY 0.2 GPH TEST <br /> F 2. MONTHLY 0.2 GPH TEST <br /> 3+ ANNUAL INTEGRITY TEST(0.1 GPH) <br /> I 3. ANNUAL INTEGRITY TEST(0.1 GPH) <br /> _.-.,.,... r 4. DAILY VISUAL CHECK <br /> CONVENTIONAL SUCTION SYSTEMS: CONVENTIONAL SUCTION SYSTEMS(Check all that apply): <br /> I 5. DAILY VISUAL MONITORING OF PUMPING SYSTEM+TRIENNIAL PIPING INTEGRITY I' 5. DAILY VISUAL MONITORING OF PIPING AND PUMPING SYSTEM <br /> TEST(0.1 GPH) I r 6. TRIENNIAL INTEGRITY TEST(0.1 GPH) <br /> SAFE SUCTION SYSTEMS(NO VALVES IN BELOW GROUND PIPING): SAFE SUCTION SYSTEMS(NO VALVES IN BELOW GROUND PIPING): <br /> F 7. SELF MONITORING r 7. SELF MONITORING <br /> GRAVITY FLOW: GRAVITY FLOW(Check all that apply): <br /> 9. BIENNIAL INTEGRITY TEST(0.1 GPH) I B. DAILY VISUAL MONITORING <br /> I 9. BIENNIAL INTEGRITY TEST(0.1 GPH) <br /> SECONDARILY CONTAINED PIPING SECONDARILY CONTAINED PIPING <br /> PRESSURIZED PIPING(Check all that apply): PRESSURIZED PIPING(Check all that apply): <br /> 10. CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL ALARMS AND 10. CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL ALARMS AND(check one) <br /> (Check one) <br /> X a. AUTO PUMP SHUT OFF WHEN A LEAK OCCURS r a. AUTO PUMP SHUT OFF WHEN A LEAK OCCURS <br /> r b. AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM r b. AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM DISCONNECTION <br /> DISCONNECTION <br /> F c. NO AUTO PUMP SHUT OFF r c. NO AUTO PUMP SHUT OFF <br /> X 11. AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST)WITH FLOW SHUT OFF OR I 11, AUTOMATIC LEAK DETECTOR <br /> RESTRICTION <br /> r 12. ANNUAL INTEGRITY TEST(0.1 GPH) I� 12. ANNUAL INTEGRITY TEST(0.1 GPH) <br /> i <br /> SUCTION/GRAVITY SYSTEM: SUCTION/GRAVITY SYSTEM: <br /> I13. CONTINUOUS SUMP SENSOR+AUDIBLE AND VISUAL ALARMS F 13. CONTINUOUS SUMP SENSOR+AUDIBLE AND VISUAL ALARMS <br /> EMERGENCY GENERATORS ONLY(Check all that apply) EMERGENCY GENERATORS ONLY(Check all that apply) <br /> r 14. CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF+AUDIBLE AND I 14. CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF+AUDIBLE AND VISUAL <br /> VISUAL ALARMS ALARMS <br /> r 15. AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST)WITHOUT FLOW SHUT OFF OR r 15. AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST) <br /> RESTRICTION <br /> r 16. ANNUAL INTEGRITY TEST(0.1 GPH) r 16. ANNUAL INTEGRITY TEST(0.1 GPH) <br /> F 17. DAILY VISU4 CHECK r 17. DAILY VISUAL CHECK <br /> VIII.,DISPENSER:CONTAINMENT <br /> DISPENSER CONTAINMENT r 1. FLOAT MECHANISM THAT SHUTS OFF SHEAR VALVE I' 4. DAILY VISUAL CHECK <br /> DATE INSTALLED 468 r 2. CONTINUOUS DISPENSER PAN SENSOR+AUDIBLE AND VISUAL ALARMS r 5. TRENCH LINER/MONITORING <br /> i <br /> 1998 X 3. CONTINUOUS DISPENSER PAN SENSOR WITH AUTO SHUT OFF FOR DISPENSER+AUDIBLE AND VISUAL ALARMS r 6. NONE 469 <br /> I certify that tha information provided herein is true and accurate t5tthe best of my knowledge. <br /> SIG RE OF OWNE PERATOR DATE 470 <br /> 4/5/02 <br /> IE OF OWNER/OPERATOR(print) 471 TITLE OF OWNER/OPERATOR 472 <br /> Bruce T. Marubashi for Shell Oil Producst US H,S&E Analyst 925-766-3498 <br /> Permit Number(For local use only) 473 I Permit Approved(For local use only) 474 Permit Expiration Date(For local use only) 475 <br /> 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.