C
>
COUNTRY CLUB
>
2575
>
2300 - Underground Storage Tank Program
>
PR0231070
>
COMPLIANCE INFO_2004-2005
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/30/2023 2:30:02 PM
Creation date
6/3/2020 9:43:34 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2004-2005
RECORD_ID
PR0231070
PE
2351
FACILITY_ID
FA0006439
FACILITY_NAME
COUNTRY CLUB MOBIL CIRCLE K
STREET_NUMBER
2575
STREET_NAME
COUNTRY CLUB
STREET_TYPE
BLVD
City
STOCKTON
Zip
95204
CURRENT_STATUS
01
SITE_LOCATION
2575 COUNTRY CLUB BLVD
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2351_PR0231070_2575 COUNTRY CLUB_2004-2005.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
531
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ULtULC Listed Red Thmadvft Piping System <br /> MOW <br /> GENERAL SPECIFICATIONS <br /> Pri ry Piping Secondary Containment Piping <br /> SCOPE SCOPE <br /> PIPE—Pipe shall be manufactured by Smith Flbercast by 8 PIPE—Pipe shall be manufactured by Smith Flbercast by a <br /> filament winding process using a thermosetting epoxy resin filament winding process using a thermosetting epoxy resin <br /> to Impregnate strands of continuous glass filaments which to Impregnate strands of continuous glass filaments w Nch <br /> are wound around a mandrel at a prescribed helix angle and are wound around a mandrel at a prescribed helix angle and <br /> under controlled tension. All pipe will be supplied with under controlled tension. <br /> matching tapered TA.B.Tm(Threaded and Banded)coupling <br /> and spigot ends or T.A.B.spigot spigot ends. CONSTRUCTION <br /> 3".6"PIPE—RED THREAD IIA pipe shall have continuous <br /> CONSTRUCT70N glass fibers filament wound at a 54°wind angle in a matrix <br /> 204"PIPE—RED THREAD IIA pipe shall have continuous of epoxy resin. Pipe shall be In compliance with ASTM <br /> glass fibers filament wound at a 540 wind angle In a matrix D2310 and classified by its designation code. Pipe shall <br /> of epoxy resin. Pipe shall be in compliance with ASTM meet all performance requirements and mechanical <br /> D2310 and classified by its designation code. Pipe shall properties,and shall be classified with the following <br /> meet all dimensional and performance requirements, designation codes: <br /> mechanical properties,and shall be classified with the Size Designation Code at 73.41 F <br /> following designation codes: 3" RTRP-11AF <br /> size Designation Code atT3A"F 41.6" RTRP-11AH <br /> 2"-3" RTRP-11AF <br /> 4" RTRP-11AH ITEMS <br /> 3"-6"PIPE—Glass fiber reinforced filament wound pipe with <br /> ITEMS Plain end by Plain end or TA.B.spigot by spigot ends. Pipe <br /> 204"PIPE—Glass fiber reinforced filament wound pipe with to be factory prooftested at the following pressures: <br /> matching tapered TA.B.(Threaded and Bonded)coupling 3'-300 psig(minimum) <br /> and spigot ends or TA.B.spigot by spigot ends. Pipe to be 4'-265 psig(minimum) <br /> factory proottested at the fbilowing pressures: 6'-265 psig(minimum) <br /> 2"-375 psig 3"-6"FrMNGS—Compression molded two-piece fittings <br /> 3"-300 psig shall be manufactured using a vinyl ester molding <br /> 4 -265 psig compound. The molding compound shall be reinforced with <br /> 2W FIMNGS—Compression molded fittings shall be a minimum of 60%chopped glass fiber. <br /> manufactured using an epoxy molding compound. The ADHESINS—Adhesh+e and curing agents shall be either <br /> compound shall be reinforced with a minimum of UL Listed 8000 or 7000 series adhesive. Consul Smith <br /> chopped glass fiber. Inline fittings are filament wound. Fibercast's Installation manual No.82160 for recommended <br /> ADHESINS—Adhesive and curing agents shall be either heat curing techniques. <br /> UL Listed 8000 or 7000 sales adhesive. <br /> Consult Smith Fibercast's Installation manual No.B2160 forJOINING TECHNIQUES <br /> recommended heat curing techniques. 3"-6"PIPE and FnMNGS—Pipe shall be joined with either <br /> 8000 or 7000 series adhesive. Fittings shell be joined with <br /> JOINING TECHNIQUES either 7000 or 8000 series adhesives and filler. Material to <br /> 2"4"PIPE and FITTINGS—Pipe and fittings shall be joined be Installed In accordance with Smith Fibercast's installation <br /> with 8000 or 7000 series adhesive using matching tapered manual W.B2160. <br /> bell/coupling and spigot. Material to be Installed In TES77NG <br /> accordance with Smith Fibercast's installation manual No. <br /> B2160. 3".6"SECONDARY CONTAINMENT PIPE SYSTEMS— <br /> Secondary containment pipe systems should be tested prior <br /> TES77NG to use to assure soundness of all joints and connections. <br /> 204"PRIMARY PIPE SYSTEMS—Primary pipe systems Consult Smith Fibercasfs Installation manual No.82100. <br /> should be tested prior to use to assure soundness of all <br /> joints and connections. Consult Smith Fibercast's <br /> Installation manual No.82160. Nom:6"occoridary containmcntpipc and flGings are riot UUULC uotod. <br /> 10 <br />
The URL can be used to link to this page
Your browser does not support the video tag.