COMPLIANCE INFO_2004-2005
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
COUNTRY CLUB
>
2575
>
2300 - Underground Storage Tank Program
>
PR0231070
>
COMPLIANCE INFO_2004-2005
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/30/2023 2:30:02 PM
Creation date
6/3/2020 9:43:34 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2004-2005
RECORD_ID
PR0231070
PE
2351
FACILITY_ID
FA0006439
FACILITY_NAME
COUNTRY CLUB MOBIL CIRCLE K
STREET_NUMBER
2575
STREET_NAME
COUNTRY CLUB
STREET_TYPE
BLVD
City
STOCKTON
Zip
95204
CURRENT_STATUS
01
SITE_LOCATION
2575 COUNTRY CLUB BLVD
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2351_PR0231070_2575 COUNTRY CLUB_2004-2005.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
531
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Maximize protection with a vacuum <br /> monitored secondary containment { <br /> system. <br /> A Secondary Containment Vacuum <br /> Sensing System for use with Weeder- ; <br /> Root's ATG Systems. The Secondaryy <br /> Containment Vacuum Sensing (SCVS) <br /> System is designed to detect leaks in double <br /> walled tanks and piping systems while <br /> helping to contain a release of product while <br /> r� <br /> under vacuum.The system consists of: <br /> • Vacuum Sensors,connected to tank, <br /> sump or piping interstices <br /> • A Submersible Turbine Pump(STP), x ` fir <br /> torovide a source of vacuum zn <br /> p w `i Id <br /> • A Smart Sensor Interface with Embedded . _t.s . .., `. _ <br /> Pressure Module in a TLS-350 Operating Temperature Rating: Console Capability <br /> Monitoring System -25 degrees C to+70 degrees C The Vacuum Sensor is compatible with <br /> the following consoles: <br /> The Vacuum Sensor is interfaced to Veeder- Cable Length: Console <br /> TLS-350R/EMC w/BIR` <br /> Root's TLS-350 Monitoring System via 8 fit TLS-350 Pius/EMC Enhanced" <br /> intrinsically safe wiring to provide system Sensor Dimensions: x-350/EMC" <br /> status,replenish rate,alarm,and diagnostic 5"high x 5"wide 2"deep `Upgrade Note:The Vacuum Sensor System requires <br /> the console to have version 24C software(or greater) <br /> information. along with an ECPU2 or ECPU w/NVMEM 1 board. <br /> Standard Models <br /> Vacuum Sensor Kits are available in a varietyIN <br /> > <br /> of models: 20- 7*" 4 Vacuum�nsor t`for steel tank <br /> 3_30020-468,469,470-471 4 Vacuum Sensor Kit`for fib lass tanks(4 6 8'10) <br /> 330020-486 4 Vacuum Sensor Kit`for no tank <br /> • For monitoring double-walled piping 33oo2o-a72 3 vacuum Sensor Kt*for steel tank <br /> 3320 473,474-475-476 3 Vacuum Sensor IGt`for fiberglass tanks(4'6'8'10') <br /> and sump interstices 3320-485 3 Vacuum Sensor Wt"for no tank <br /> • For monitoring double-walled steel tank 330020 479 2 vacuum Sensor K t`for steel tank <br /> interstices(see back page) 330020-481,-482.-483,-484 2 Vacuum Sensor Kir for fiberglass tanks_W,6',8'.10) <br /> 330020-480 2 Vacuum Sensor Kit`for no tank <br /> • For double-walled fiberglass tanks 330020-495 1 Vacuum Sensor Kit'for no tank <br /> 857280-100 Vacuum Sensor for piping&sumps <br /> These kits differ in the number of vacuum 857280-200 Vacuum Sensor for steel tanks <br /> 857280-301-302,-303,-304 Vacuum Sensor for fiberglass tanks(4',6',8',101) <br /> sensors and the configuration of associated 330020-aa8 Mounting Kit <br /> liquid sensors. An inline kit mounted liquid 332217-001 Relief Valve Assembly <br /> sensor is used for Vacuum Sensors 332250-001 Smart Sensor w/Embedded Pressure Sensor Module(7 Channep" <br /> monitoring piping and sumps. An external A� 00-0--,- M4 " 1101. ,. „ +�lri f <br /> liquid sensor(to be installed in the secondary 1/4"NPT Ba't'ed Fittings 3 330020-487 <br /> li <br /> q ry 1/4"NPT Barbed Fittings 15 330020-488 <br /> space at the bottom of the tank)is provided 1/4"NPT Barbed Fittings 25 330020-489 <br /> with one of the Vacuum Sensors in the steel Barbed Tee 1 576008-657 <br /> Vacuum Hose 25' 25' 332310-001 <br /> and fiberglass tank kits to monitor the tank. Vacuum Hose 50' 50' 332310-002 <br /> Vacuum Hose 100' 100' 332310-003 <br /> 3—way Ball Valve 1 576008-649 <br /> Schrader Valve Barbed Fitting 3 330020-496 <br /> Schrader Valve Barbed Riding 15 330020-497 <br /> ' IGts include mounting bracket,6'of vacmun hose,ref vahm assembly lfi requkeo and the appropriate number of HWd sensors, <br /> 3-way ball valves,barbed fittings and hose clamps so that each vausim sensor can monitor a single tank,sump or piping interstices. <br /> The Vacwm Sensing System reOms one 7 da nd Smart Sensor Intedace with Embedded Pressure Module,8 channel Smart <br /> Sensor Modules(p/n 329356-004)can be used for Vacuum Sensors eVkt and abate. <br /> 3A NO <br /> 1 VEE®E - C <br />
The URL can be used to link to this page
Your browser does not support the video tag.