I <br /> D. Results of Testing/Servicing <br /> Software Version Installed: 327.01 <br /> mplete the following checklist: <br /> S Yes ❑ No* Is the audible alarm operational? <br /> S Yes ❑ No* Is the visual alarm operational? <br /> S Yes ❑ No* Were all sensors visually inspected,functionally tested,and confirmed operational? <br /> S Yes O No* Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will not interfere with their proper <br /> operation? <br /> ❑ Yes ❑ No* If alarms are relayed to a remote monitoring station,is all communications equipment(e.g.,modem)operational? <br /> S N/A <br /> S Yes ❑ No* For pressurized piping systems,does the turbine automatically shut down if the piping secondary containment monitoring system detects a leak, <br /> ❑ N/A fails to operate, or is electrically disconnected? If yes: which sensors initiate positive shut-down? (Check all that apply) S Sump/Trench <br /> Sensors; S Dispenser Containment Sensors. <br /> Did you confirm positive shut-down due to leaks and sensor failure/disconnection? S Yes; ❑No. <br /> S Yes O No* For tank systems that utilize the monitoring system as the primary tank overfill warning device(i.e., no mechanical overfill prevention valve is <br /> ❑ N/A installed),is the overfill warning alarm visible and audible at the tank fill points)and operating properly? If so,at what percent of tank capacity <br /> does the alarm trigger? 90% <br /> ❑ Yes S No Was any monitoring equipment replaced? If yes,identify specific sensors,probes,or other equipment replaced and list the manufacturer name <br /> and model for all replacement parts in Section E,below. <br /> SYes* ❑ No Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply) <br /> ❑Product; S Water. If yes,describe causes in Section E,below. <br /> S Yes O No* Was monitoring system set-up reviewed to ensure proper settings?Attach set up reports,if applicable <br /> S Yes ❑ No* Is all monitoring equipment operational per manufacturer's specifications? <br /> *In Section E below,describe how and when these deficiencies were or will be corrected. <br /> WATER FOUND IN SUMPS CLEANED OUT AND PUT IN HAZ WASTE ON SITE .91 product sump s3 <br /> would not go into no vac and could not get high liquid alarm on it because the cap is glued shut . cust <br /> Comments: called cent petrolem to repair and retest <br /> Monitoring System Certification Page 2 of 4 2/21/07 <br />