COMPLIANCE INFO_2006-2011
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
COUNTRY CLUB
>
2575
>
2300 - Underground Storage Tank Program
>
PR0231070
>
COMPLIANCE INFO_2006-2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/22/2023 1:52:51 PM
Creation date
6/3/2020 9:43:34 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006-2011
RECORD_ID
PR0231070
PE
2351
FACILITY_ID
FA0006439
FACILITY_NAME
COUNTRY CLUB MOBIL CIRCLE K
STREET_NUMBER
2575
STREET_NAME
COUNTRY CLUB
STREET_TYPE
BLVD
City
STOCKTON
Zip
95204
CURRENT_STATUS
01
SITE_LOCATION
2575 COUNTRY CLUB BLVD
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2351_PR0231070_2575 COUNTRY CLUB_2006-2011.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
449
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
AVA <br /> a <br /> Maximize protection with a vacuum <br /> # <br /> monitored secondary containment ,. <br /> system. <br /> A Secondary Containment Vacuum Features and Benefits Facilitates periodic operability testing <br /> Sensing System for use with Veeder- Satisfy Requirements Leverage Existing Veeder-Root Systems <br /> • Certified to meet California's requirement for <br /> Root's ATG Systems. The Secondary secondary space monitoring for lanits and lines Uses STP as the vacuum source and works with <br /> seco <br /> Containment Vacuum Sensing (SCVS) seorequired AB 2481 Red Jacket and FE STPs <br /> y • Installs in die STP sump and connects to the <br /> System is designed to detect leaks in double- • Satisfies the requirements for Class 1 Leak console via intrinsically safe wiring <br /> walled tanks and piping systems while Detection as defined by the European . Able to share wiring conduit with other <br /> helping to contain a release of product while Standard EN 13160-23rd Patty,National Work Group and LG113 Veeder-Root intrinsically safe(IS)probes and <br /> under vacuum. The system consists of: listed sensors including sump or line leak sensors <br /> • Interfaces to the Smart Sensor Interface with <br /> • Vacuum Sensors,connected to tank, Reduce Exposure to Risk Embedded Pressure Module <br /> • Alarms when vacuum cannot be ma ntained Provides for positive shut down of pressurized <br /> sump or piping interstices lines when required <br /> • A Submersible Turbine Pump(STP), or when replenish rate exceeds 85 liters per hour • Simple installation,no need to mess with brine <br /> • The system alarms when liquid is detected in <br /> to provide a source of vacuum the secondary space <br /> • A Smart Sensor Interface with Embedded <br /> Pressure Module in a TI-S-350 Operating Temperature Rating: Console Capability <br /> Monitoring System -25 degrees C to+70 degrees C The Vacuum Sensor is compatible with <br /> the following consoles: <br /> Cable Length: Console <br /> The Vacuum Sensor is interfaced to Veeder- 8 feet TLS-350R/EMC w/BIR' <br /> Root's TLS-350 Monitoring System via TLS-350 Plus/EMC Enhanced` <br /> intrinsically safe wiring to provide system Sensor Dimensions' TLS-350/EMC' <br /> status,replenish rale,alarm,and diagnostic 'Upgrade Note:The Vacuum Sensor System requires <br /> p g 5"high x 5"wide 2"deep the console to have version 24C software(or greater) <br /> information. along with an ECPU2 or ECPU w/NVMEM 1 board. <br /> Standard Models <br /> Vacuum Sensor Kits are available in a variety Veeder-Root P/N Description <br /> of models: 330020-467 4 Vacuum Sensor Kit'for steel tank <br /> 330020-468,-469,-470,-471 4 Vacuum Sensor Wt'for fiberglass tanks(4',6,8',10) <br /> 330020-486 4 Vacuum Sensor Kit'for no tank <br /> • For monitoring double-walled piping 330020-472 3 Vacuum Sensor KR'for steel tank <br /> 330020-473,-474,-475,-476 _ 3 Vacuum Sensor Kit'for fiberglass tanks(4',6',8',10') <br /> and sum interstices - - <br /> p 330020-485 3 Vacuum Sensor Kir`for no tank <br /> • For monitoring double-walled steel tank 330020-479 _._ 2 vacuum Sensor Kit'for_steel-tank- <br /> 330020-481.-482,-483,-484 <br /> ank <br /> 330020-481-482,-483,-484 2 Vacuum Sensor Kit'for fiberglass tanks(4',6',8',10') <br /> interstices(see back page) <br /> - _ - <br /> 330020-480 2 Vacuum Sensor Kit*for no tan <br /> • For double-walled fiberglass tanks 330020-495 1 Vacuum Sensor Kit'for no tank <br /> 857280-100 Vacuum Sensor for piping&sumps <br /> 857280-200 Vacuum Sensor for steel tanks <br /> These kits differ in the number of vacuum <br /> 857280-301,-302,-303,-304 Vacuum Sensor for fiberglass tanks(4',6',8',101) <br /> sensors and the configuration of associated 330020-448 Mounting Kit <br /> liquid sensors. An inline kit mounted liquid 332217-001 Relief Valve Assembly <br /> 332250-001 Smart Sensor w/Embedded Pressure Sensor Module(7 Channel)" <br /> sensor is used for Vacuum Sensors <br /> monitoring piping and sumps. An external Accessories Part Description Quantity/Length Part Number <br /> 1/4'NPT Barbed Fittings 3 330020-487 <br /> liquid sensor(to be installed in the secondary 1/4"NPT Barbed Fittings 15 330020-488 <br /> space at the bottom of the tank) is provided 1/4"NPT Barbed Fittings - 25 330020-489 <br /> with one of the Vacuum Sensors in the steel Barbed Tee 1 576008-657 <br /> Vacuum Hose 25 25' 332310-001 <br /> - <br /> and fiberglass tank kits to monitor the tank. Vacuum Hose 50' 501 332310-002 -_ <br /> Vacuum Hose 100' 100' 332310-003 <br /> 371hay Ball Valve _ 1 576008-649 _- <br /> Schrader Valve Barbed Fitting 3 330020-496 <br /> Schrader Valve Barbed Fitting 15 330020-497 <br /> Kits include mounting bracket,6'of vacuum hose,relief valve assembly(if required)and the appropriate number of liquid sensors, <br /> 3-way ball valves, barbed fittings and hose clamps so that each vacuum sensor can monitor a single tank,sump or piping interstices. <br /> "The Vacuum Sensing System requires one 7 channel Smart Sensor Interface with Embedded Pressure Module,8 channel Smart <br /> Sensor Modules(p/n 329356-004)can be used for Vacuum Sensors eight and above. <br /> For more information call: 1-888-561-7942 <br /> tl VEEDER-ROOT <br />
The URL can be used to link to this page
Your browser does not support the video tag.