Laserfiche WebLink
Maximize protection <br />vacuum <br />monitored secondary containment <br />system. <br />A Secondary Containment Vacuum <br />Sensing System for use with Veeder- <br />Root's ATG Systems. The Secondary <br />Containment Vacuum Sensing (SCVS) <br />System is designed to detect leaks in double - <br />walled tanks and piping systems while <br />helping to contain a release of product while <br />under vacuum. The system consists of: <br />Vacuum Sensors, connected to tank, <br />sump or piping interstices <br />A Submersible Turbine Pump (STP), <br />to provide a source of vacuum <br />A Smart Sensor Interface with Embedded <br />Pressure Module in a TLS -350 <br />Monitoring System <br />The Vacuum Sensor is interfaced to Veeder- <br />Rool's TLS -350 Monitoring System via <br />intrinsically safe wiring to provide system <br />status, replenish rate, alarm, and diagnostic <br />information. <br />Vacuum Sensor Kits are available in a variety <br />of models: <br />• For monitoring double -walled piping <br />and sump interstices <br />• For monitoring double -walled steel tank <br />interstices (see back page) <br />• For double -walled fiberglass tanks <br />These kits differ in the number of vacuum <br />sensors and the configuration of associated <br />liquid sensors. An inline kit mounted liquid <br />sensor is used for Vacuum Sensors <br />monitoring piping and sumps. An external <br />liquid sensor (to be installed in the secondary <br />space at the bottom of the tank) is provided <br />with one of the Vacuum Sensors in the steel <br />and fiberglass tank kits to monitor the tank. <br />Features and Benefits <br />Satisfy Requirements <br />• Certified to meet California's requirement for <br />secondary space monitoring for tanks and lines <br />as required by AB 2481 <br />• Satisfies dne requirements for Class I Leak <br />Detection as defined by the European <br />Standard EN 13160-2 <br />• 3rd Party, National Work Group and LG113 <br />listed <br />Reduce Exposure to Risk <br />• Alanns when vacuum cannot be maintained <br />or when replenish rate exceeds 85 Liter per hour <br />• The system alarms when liquid is detected in <br />die secondary space <br />Facilitates periodic operability testing <br />Leverage Existing Ueeder-Root Systems <br />• Uses STP as the vacuum source and works with <br />Red Jacket and FE STPs <br />• Installs in die STP sump and connects to the <br />console via intrinsically safe wiring <br />• Able to share wiring conduit with other <br />Ueeder-Root intrinsically safe (1S) probes and <br />sensors Including sump or line leak sensors <br />• Interfaces to the Smut Sensor Interface wide <br />Embedded Pressure Module <br />• Provides for positive shut down of pressurized <br />lines when required <br />• Simple installation, no need to mess with brine <br />Operating Temperature Rating: Console Capability <br />-25 degrees C to +70 degrees C <br />The Vacuum Sensor is compatible with <br />the following consoles: <br />Cable Length: <br />Console <br />8 feet <br />TLS-350R/EMC w/BIR" <br />TLS -350 Plus/EMC Enhanced' <br />Sensor Dimensions: <br />TLS-350/EMC* <br />5" high x 5" wide 2" deep <br />'Upgrade Note: The Vacuum Sensor System requires <br />the console to have version 24C software (or greater) <br />along with an ECPU2 or ECPU w/ NVMEM 1 board. <br />Standard Models <br />Veeder-Root P/N <br />Description <br />330020-467 <br />4 Vacuum Sensor Kit' for steel tank <br />330020-468,469,470,471 <br />4 Vacuum Sensor Kit' for fiberglass tanks (4',6',8',10') <br />330020-486 <br />4 Vacuum Sensor Kit' for no tank <br />330020-472 <br />3 Vacuum Sensor Kit" for steel tank <br />330020-473,474,475,476 <br />3 Vacuum Sensor Kit' for fiberglass tanks (4',6',8', 10') <br />330020-485 <br />3 Vacuum Sensor Kit' for no tank <br />330020-479 <br />2 Vacuum Sensor Kit' for steel tank <br />330020-481,-482,-483,-484 <br />2 Vacuum Sensor Kit' for fiberglass tanks (4',6',8', 10') <br />330020-480 <br />2 Vacuum Sensor Kit' for no tank <br />330020-495 <br />1 Vacuum Sensor Kit' for no tank - - <br />857280-100 <br />Vacuum Sensor for piping & sumps <br />857280-200 <br />Vacuum Sensor for steel tanks <br />857280-301 302,-303,-304 <br />Vacuum Sensor for fiberglass tanks (4 ,6 8' 101 <br />330020-448 <br />Mounting Kit <br />332217-001 <br />Relief Valve Assembly <br />332250-001 <br />Smart Sensor w/Embedded Pressure Sensor Module (7 Channeq" <br />Accessories Part Description <br />Quantity/Length Part Number <br />1/4" NPT Barbed Fittings <br />— 3 _ 330020-487 - <br />1/4- NPT Barbed Fittings- <br />15 330020-488 <br />1/4" NPT Barbed Fittings _ <br />_ 2. 5 _ 330020-489 <br />Barbed Tee <br />1 576008-657 <br />Vacuum Hose 25' <br />25'- -- 332310-001 <br />Vacuum Hose 50' <br />50' 332310-002 <br />Vacuum Hose 100' <br />100' 332310-003 <br />3 -Way Ball Valve <br />1 _ 576008-649 _ <br />Schrader Valve Barbed Fitting <br />3 330020-496 <br />Schrader Valve Barbed Fitting <br />15 330020-497 <br />' Kits include mounting bracket, 6' of vacuum <br />hose, relief valve assembly (if required) and the appropriate number of liquid sensors, <br />3 -way ball valves, barbed fittings and hose <br />clamps so that each vacuum sensor can monitor a single tank, sump or piping interstices. <br />" The Vacuum Sensing System requires one 7 <br />channel Smart Sensor Interface with Embedded Pressure Module. 8 channel Smart <br />Sensor Modules (p/n 329356-004) can be used for Vacuum Sensors eight and above. <br />For more information call: 1-888-561-7942 <br />VEEDER-ROOT <br />