My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2012-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
COUNTRY CLUB
>
2575
>
2300 - Underground Storage Tank Program
>
PR0231070
>
COMPLIANCE INFO_2012-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/22/2023 4:20:12 PM
Creation date
6/3/2020 9:43:36 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012-2018
RECORD_ID
PR0231070
PE
2351
FACILITY_ID
FA0006439
FACILITY_NAME
COUNTRY CLUB MOBIL CIRCLE K
STREET_NUMBER
2575
STREET_NAME
COUNTRY CLUB
STREET_TYPE
BLVD
City
STOCKTON
Zip
95204
CURRENT_STATUS
01
SITE_LOCATION
2575 COUNTRY CLUB BLVD
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2351_PR0231070_2575 COUNTRY CLUB_2012-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
391
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Time In: <br /> Time Out: <br /> aR4u!!Y, San Joaquin County <br /> :< <br /> Environmental Health Department <br /> W. <br /> 1868 East Hazelton Avenue, Stockton, CA95205-6232 <br /> • �. ;a• Telephone: (209)468-3420 Fax: (209)464-0138 Web:www.sjgov.org/ehd <br /> Un erground Storage Tank Program Service Request Inspection Report <br /> Name of Facility: Country Club Valero Date: 04/27/2018 <br /> Address: 2575 COUNTRY CLUB BLVD, STOCKTON 95204 <br /> Requestor: MARK VENDEIRO, CALIFORNIA FUEL SUPPLY Telephone: <br /> Program Element: 2308 - UST RETROFIT Request#: SR0078931 <br /> Inspection Type: 298 - UST RETROFIT REPAIR INSPECTION <br /> Onsite Service Technician: Steven Jones ICC Service Tech/Installer Exp. Date: 07/05/2019 <br /> Manufacturer training: <br /> 0VERALLsINSPECTI0N ®SES AND COMMENTS <br /> .- <br /> NOTES <br /> Conducted visual inspection of the filters within the UDCs and verification of the dispenser footprint contained by the UDCs and <br /> deflectors plates. <br /> This facility is approved to operate. <br /> The person in charge is responsible for ensuring that the above mentioned facility is in compliance with all applicable sections of the California Health and <br /> Safety Code. If a reinspection is required,fees will be assessed at the current hourly rate. <br /> Received by: Name and Title: Steven Jones, Installer <br /> EH Specialist: STACY RIVERA Phone: (209) 468-3440 <br /> FAD006439 SR0078931 SC298 04/27/2018 <br /> EHD 23-01 Rev.06/30/15 Page 1 of 1 Underground Storage Tank Program Service Request Inspection Report <br />
The URL can be used to link to this page
Your browser does not support the video tag.