My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2012-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
COUNTRY CLUB
>
2575
>
2300 - Underground Storage Tank Program
>
PR0231070
>
COMPLIANCE INFO_2012-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/22/2023 4:20:12 PM
Creation date
6/3/2020 9:43:36 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012-2018
RECORD_ID
PR0231070
PE
2351
FACILITY_ID
FA0006439
FACILITY_NAME
COUNTRY CLUB MOBIL CIRCLE K
STREET_NUMBER
2575
STREET_NAME
COUNTRY CLUB
STREET_TYPE
BLVD
City
STOCKTON
Zip
95204
CURRENT_STATUS
01
SITE_LOCATION
2575 COUNTRY CLUB BLVD
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2351_PR0231070_2575 COUNTRY CLUB_2012-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
391
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN 3,JO A Q O I N Environmental Health Department <br /> --COUNTY U <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> Country Club Valero 2575 COUNTRY CLUB BLVD, Stockton January 29, 2018 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS ll,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 305 HSC 25290.1(e)VPH monitoring of the interstitial spaces of the UST system is not maintained. <br /> The following was noted at the time of inspection: <br /> The communication of the interstitial space inside the Under Dispenser Containment(UDC)7/8 failed when tested, <br /> indicating that no continuous communication exists between the entire interstitial space. <br /> The underground tank system shall be designed and constructed with a continuous monitoring system capable of <br /> detecting the entry of the liquid or vapor-phase of the hazardous substance stored in the primary containment into <br /> the secondary containment and capable of detecting water intrusion into the secondary containment. Correct <br /> immediately by having a properly licensed,trained, and certified contractor replace the failed component with a <br /> functional component(LG 113-x listed, if applicable)and obtain a permit within one business day from the EHD. If <br /> the failed component can't be replaced immediately,there is a possibility that the UST system may be red tagged to <br /> prevent fuel inputs. <br /> This is a repeat violation, Class II. <br /> 316 HSC 25290.1(c3), 25290.2(c3)Secondary containment not constructed to prevent water intrusion(after Jul 2003). <br /> Liquid was found in the 91 Submersible turbine Pump(STP)sump,diesel STP sump,diesel fill sump, and 87 fill <br /> sump. Secondary containment shall be constructed to prevent any water intrusion into the system by precipitation, <br /> infiltration, or surface runoff. Immediately remove this liquid, make a hazardous waste determination per Title 22 <br /> hazardous waste regulations, and manage accordingly. Immediately contact a properly licensed, trained, and <br /> certified contractor to address the water intrusion into the 91 STP sump,diesel STP sump,diesel fill sump and 87 fill <br /> sump under permit and inspection of the EHD. <br /> This is a repeat violation, Class II. <br /> Overall Inspection Comments: <br /> An inspection checklist was provided to the facility operator at the time of inspection. The EHD will generate <br /> and provide a complete report to the facility operator. <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, within 30 days of receiving the complete inspection report. <br /> 1) If the 87, 91 and Diesel spill containers fail in the future during operation or testing they shall be replaced <br /> under EHD permit and inspection and comply with Title 23 CCR Section 2635(b). <br /> AFTER THE COMPLIANCE DATE,EHD WILL BILL FOR ALL TIME AND ACTIVITIES ASSOCIATED WITH BRINGING <br /> THIS FACILITY BACK INTO COMPLIANCE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> Received by: Date: Inspector. Inspector Phone: <br /> Printed Name and Title: ZUNA BARKER, EHS Trainee (209)953-7311 <br /> FA0006439 PR0231070 SCO01 01/29/2018 <br /> EHD 23-01 Rev,10/31/2017 Page 5 of 5 Underground Storage Tank Program OR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.