My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2007-2008
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
FAIRMONT
>
975
>
2300 - Underground Storage Tank Program
>
PR0231331
>
COMPLIANCE INFO_2007-2008
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/20/2023 10:36:46 AM
Creation date
6/3/2020 9:43:39 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2007-2008
RECORD_ID
PR0231331
PE
2351
FACILITY_ID
FA0000513
FACILITY_NAME
LODI MEMORIAL HOSPITAL
STREET_NUMBER
975
Direction
S
STREET_NAME
FAIRMONT
STREET_TYPE
AVE
City
LODI
Zip
95240
APN
03107039
CURRENT_STATUS
01
SITE_LOCATION
975 S FAIRMONT AVE
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2351_PR0231331_975 S FAIRMONT_2007-2008.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
347
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
LG 162-2 - 6 - <br /> Guidance <br /> 6 -Guidance (LG) Letter 113. LG 113 can be found on our website at: <br /> http://www.waterboards.ca.gov/ust/leak prevention/lgll3/index.html <br /> It is important to note that regulated piping begins where piping exits/enters the <br /> tank and continues to the point where piping extends above the surface of the <br /> ground (e.g., at a shear valve). Statute does not provide an exemption for single- <br /> walled piping transitions contained in sumps, or single-walled piping transitions in <br /> UDCs, or fill piping contained in sumps. The following options may be used to <br /> satisfy the requirements for single-walled piping transitions contained in sumps; <br /> single-walled piping transitions contained in UDCs; and fill piping contained in <br /> sumps: <br /> L The entire piping length, including piping within sumps or UDCs, must be <br /> double-walled and continuously monitored using vacuum, pressure, or <br /> interstitial liquid level measurement methods; or <br /> ii. The interstitial space between the primary (i.e., single-walled transition <br /> pipe or fill piping) and secondary containment (i.e., sump, UDC) must be <br /> continuously monitored using vacuum or pressure. (Note: Interstitial liquid <br /> level measuroment would not be appropriate for this option.); or <br /> ill. The single-walled transition pipe or fill piping must be contained within a <br /> double-walled sump and/or double-walled UDC that either: (1) extends to <br /> the surface or (2) has a double-walled product tight lid that is continuously <br /> monitored using vacuum, pressure, or interstitial liquid level measurement <br /> methods. The secondary containment (of the sump or UDC, including <br /> penetration fittings) must be continuously monitored using vacuum, <br /> pressure, or interstitial liquid level measurement methods. <br /> Pursuant to Section 2637(a)(6) of Title 23, CCR, portions of the UST system <br /> which are continuously monitored using vacuum, pressure, or interstitial liquid <br /> level measurement methods are exempt from periodic secondary containment <br /> testing. Therefore, periodic secondary containment testing is not required for <br /> secondary containment of tank and piping that are continuously monitored using <br /> vacuum, pressure, or interstitial liquid level measurement methods. Please note <br /> that annual certification of the leak detection equipment is still required. <br /> B. What components of USTs installed on or after July 1, 2004 are required to <br /> be monitored in accordance with H&S Code, Section 25290.1(d)? <br /> Section 25290.1 requires that the "underground storage tank system" be <br /> designed and constructed with a continuous monitoring system. Tank and <br /> product piping moni'►,)red using constant vacuum, pressure, or interstitial liquid <br /> level measurement methods satisfy this requirement through Section 25290.1(e). <br /> However, other parts of the UST system not subject to Section 25290.1(e) must <br /> satisfy the monitoring requirement in Section 25290.1(d). These components <br /> include, but are not limited to, riser piping and access points on top of the tank, <br /> California Environmental Protection Agency <br /> �a Recycled Paper <br />