COMPLIANCE INFO_2009-2014
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
FAIRMONT
>
975
>
2300 - Underground Storage Tank Program
>
PR0231331
>
COMPLIANCE INFO_2009-2014
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/4/2021 1:20:05 PM
Creation date
6/3/2020 9:44:05 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009-2014
RECORD_ID
PR0231331
PE
2351
FACILITY_ID
FA0000513
FACILITY_NAME
LODI MEMORIAL HOSPITAL
STREET_NUMBER
975
Direction
S
STREET_NAME
FAIRMONT
STREET_TYPE
AVE
City
LODI
Zip
95240
APN
03107039
CURRENT_STATUS
01
SITE_LOCATION
975 S FAIRMONT AVE
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2351_PR0231331_975 S FAIRMONT_2009-2014.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
453
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
IN-TANKPRESSURE LINE LEAK; SETUP <br /> SETUP- - - - - - - - - - - - - - - - - - OUTPUT REL- SETUP <br /> - - - - <br /> T 1 :DIESEL FUEL Q 1 :DIESEL SUPPLY LINE R 1 :OVERFILL ALARM <br /> PRODUCT CODE 1 TYPE: <br /> THERMAL COEFF : .000450 TYP:USER DEFINED STANDARD <br /> TANK; DIAMETER 119.60 IST LINE LEN: 60 FEET NORMALLY OPEN <br /> TANK PROFILE 4 PTS 2ND LINE LEN: 0 FEET <br /> FULL VOL 19951 IST LINE DIAM: 1 .50 IN. <br /> 89.7 INCH VOL 16204 IST BULK MOD: 8600 PSI IN-TANK; ALARMS <br /> 59.8 INCH VOL 9976 THERMAL COEFF :0.000450 ALL:OVERFILL ALARM <br /> 29.9 INCH VOL 3790 SHUTDOWN RATE: NONE ALL:HIGH PRODUCT ALARM <br /> LOW PRESSURE SHUTOFF:NO ALL:MA`, PRODUCT ALARM <br /> LOW PRESSURE 10 PSI <br /> FLOAT SIZE: 4.0 IN. R 2:BUILDING MGT SYSTEM <br /> T 1 :DIESEL FUEL TYPE: <br /> WATER WARNING 2.0 DISPENSE MODE: STANDARD <br /> HIGH WATER LIMIT: 3.0 STANDARD NORMALLY OPEN <br /> SENSOR: NON-VENTED <br /> MAX OR LABEL VOL: 19951 PRESSURE OFFSET: O.OPSI <br /> OVERFILL LIMIT 90% IN-TANK ALARMS <br /> 17956 MECHANICAL BLENDER: NO ALL:HIGH WATER ALARM <br /> HIGH PRODUCT 95% <br /> AL,L:OVERFILL ALARM <br /> 18953 <br /> DELIVERY LIMIT 153 ALL:LOW LOW PRODUCT ALARM <br /> ALL:SUDDEN LOSS ALARM <br /> 2992 ALL:HIGH PRODUCT ALARM <br /> LOW PRODUCT420 ALL: INVALID FUEL LEVEL <br /> LEAK ALARM LIMIT: 99 ALL:PROBE OUT <br /> SUDDEN LOSS LIMIT: 1000 ALL:HIGH WATER NEEDED JG <br /> ALL:DELTVEk1 NEEDED <br /> TANK TILT 0.00 ALL:MAX PRODUCT ALARM <br /> PROBE OFFSET 0.00 <br /> LIQUID SENSOR ALMS <br /> ALL:FUEL ALARM <br /> SIPHON MANIFOLDED TANKS LINE LEAK LOCKOUT SETUP ALL:SENSOR OUT ALARM <br /> TO: NONE - - - - - - - ALL:SHORT ALARM <br /> LINE MANIFOLDED TANKS LOCKOUT SCHEDULE ALL:WATER ALARM <br /> T#: NONE DAILY , ' ALL:WATER OUT ALARM <br /> START TIME: DISABLED ALL:HIGH LIQUID ALARM <br /> STOP TIME DISABLED ALL:LOW LIQUID ALARM <br /> LEAK MIN PERIODIC: 0% ALL:LIQUID WARNING <br /> 0 <br /> LEAK MINANNUAL 0°S PRESSURE LINE LEAK <br /> ALL:GROSS LINE FAIL <br /> 0 <br /> ALL:PLLD OPEN ALARM <br /> ALL:PLLD SHUTDOWN ALARM <br /> PERIODIC TEST TYPE ALL:FUEL OUT <br /> STANDARD SMARTSENSOR ALARMS <br /> ALL:COMMUNICATION ALARM <br /> ANNUAL TES'I'' FAIL ALL:SENSOR FAULT ALARM <br /> ALARM DISABLED ALL:FUEL WARNING <br /> LIQUID SENSOR SETUP <br /> PERIODIC TET FAIL - - - - - - - - - - - - <br /> ALL:FUEL ALAR <br /> ALARM DISABLED <br /> ALARM <br /> L 1 :VENT TRNS SUMPBRINE PLL:WATER WARNING <br /> GROSS TEST FAIL TRI-STATE (SINGLE FLOAT) ALL:WATER ALARM <br /> ALL:HIGH LIQUID WARNING <br /> ALARM DISABLED CATEGORY : PIPING SUMP ALL:HIGH LIQUID ALARM <br /> ANN TEST AVERAGING: OFF ALL:LOW LIQUID WARNING <br /> ALL:LOW LIQUID ALARM <br /> PER TEST AVERAGING: OFF L 2:LINE TRNS SUMP BRINE ALL:TEMPERATURE WARNING <br /> TRI-STATE (SINGLE FLOAT) ALL:RELAY ACTIVE <br /> TANK TEST NOTIFY: OFF CATEGORY : PIPING SUMP ALL:INSTALL ALARM <br /> ALL:SENSOR FAULT WARN <br /> TNK TST SIPHON BREAK OFF ALL:VACUUM WARNING <br /> L 3:DIESELTANK ANNULAR ALL:NO VACUUM ALARM <br /> DELIVERY DELAY 5 MIN DUAL POINT H'Y'DROSTATIC <br /> PUMP THRESHOLD 10.00% CATEGORY : ANNULAR SPACE <br /> LEAK; TEST METHOD <br /> TEST ON DATE : ALL TANK: L 4:RMTE FILL SUMP BRINE <br /> JUL 23. 2010 TRI-STATE (SINGLE FLOAT) <br /> START TIME : DI:CABLED CATEGORY : PIPING SUMP <br /> TEST RATE :0.20 GAL/HR <br /> DURATION : 2 HOURS <br /> TST EARLY STOP:IiISABLED L 5:TANK FILL SUMP BRINE <br /> TRI-STATE (SINGLE FLOAT) PLLD LINE DISABLE SETUP <br /> LEAK: TEST REPORT FORMAT CATEGORY : PIPING SUMP - - - - - - - - - - - - <br /> NORMAL <br /> 0 1 :D I ESEL SUPPLY LINE <br /> L 6:DIESEL. TURB SUMP BRN - NO ALARM ASSIGNMENTS - <br /> TRI-STATE (SINGLE FLOAT) <br /> CATEGORY : STP 21-IMP <br />