My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2009-2014
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
FAIRMONT
>
975
>
2300 - Underground Storage Tank Program
>
PR0231331
>
COMPLIANCE INFO_2009-2014
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/4/2021 1:20:05 PM
Creation date
6/3/2020 9:44:05 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009-2014
RECORD_ID
PR0231331
PE
2351
FACILITY_ID
FA0000513
FACILITY_NAME
LODI MEMORIAL HOSPITAL
STREET_NUMBER
975
Direction
S
STREET_NAME
FAIRMONT
STREET_TYPE
AVE
City
LODI
Zip
95240
APN
03107039
CURRENT_STATUS
01
SITE_LOCATION
975 S FAIRMONT AVE
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2351_PR0231331_975 S FAIRMONT_2009-2014.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
453
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Monitoring System Certification Form:Addendum for Vacuum/Pressure Interstitial Sensors <br /> NOV 10 2014, <br /> I. Results of Vacuum/Pressure Monitoring Equipment Testing <br /> s <br /> This page should be used to document testing and servicing of vacuum and pressure if'6h i or s'-`,`A:-,bdp�'-ALTI H <br /> this form must be included with the Monitoring System Certification Form, which must be,,'prqvided-1--'t9,-the=Lank <br /> system owner/operator. The owner/operator must submit a copy of the Monitoring System Certification Form to the <br /> local agency regulating UST systems within 30 days of test date. <br /> Manufacturer:VEEDER ROOT Model:TLS350 System Type: El Pressure; 0 Vacuum <br /> Sensor ID <br /> Component(s)Monitored by this Sensor: FUEL OIL RETURN LINE <br /> S1 <br /> Sensor Functionality Test Result: ®Pass; El Fail Interstitial Communication Test Result: ®Pass; El Fail <br /> Component(s)Monitored by this Sensor: FUEL OIL SUPPLY OIL LINE <br /> S2 Sensor Functionality Test Result: Z Pass; El Fail Interstitial Communication Test Result: Z Pass; 0 Fail <br /> Component(s)Monitored by this Sensor: VENT LINE <br /> S3 Sensor Functionality Test Result: Z Pass; El Fail Interstitial Communication Test Result: Z Pass; El Fail <br /> S4 Component(s)Monitored by this Sensor: REMOTE FILL LINE <br /> Sensor Functionality Test Result: Z Pass; El Fail Interstitial Communication Test Result: Z Pass; El Fail <br /> Component(s)Monitored by this Sensor: <br /> Sensor Functionality Test Result: D Pass; El Fail Interstitial Communication Test Result: El Pass; El Fail <br /> Component(s)Monitored by this Sensor: <br /> Sensor Functionality Test Result: El Pass; El Fail Interstitial Communication Test Result: 0 Pass; El Fail <br /> Component(s)Monitored by this Sensor: <br /> Sensor Functionality Test Result: El Pass; El Fail Interstitial Communication Test Result: 0 Pass; El Fail <br /> Component(s)Monitored by this Sensor: <br /> Sensor Functionality Test Result: El Pass; El Fail Interstitial Communication Test Result: 0 Pass; El Fail <br /> Component(s)Monitored by this Sensor: <br /> Sensor Functionality Test Result: El Pass; El Fail Interstitial Communication Test Result: El Pass; D Fail <br /> Component(s)Monitored by this Sensor: <br /> Sensor Functionality Test Result: D Pass; El Fail Interstitial Communication Test Result: D Pass; El Fail <br /> How was interstitial communication verified? <br /> El Leak Introduced at Far End of Interstitial Space;' [:1 Gauge; Z Visual Inspection; El Other(Describe in Sec. J, below) <br /> Was vacuum/pressure restored to operating levels in all interstitial spaces? Z Yes F]No(If no, describe in See.J, below) <br /> J. Comments: Lodi Memorial Hospital 10-9-14 Lodi CA <br /> Page 4 of 4 <br /> If the sensor successfully detects a simulated vacuum/pressure leak introduced in the interstitial space at the furthest point from the <br /> sensor,vacuum/pressure has been demonstrated to be communicating throughout the interstice. <br /> UN-036A-1/1 www.unidocs.org Rev.01/26/06 <br />
The URL can be used to link to this page
Your browser does not support the video tag.