My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2009-2014
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
FAIRMONT
>
975
>
2300 - Underground Storage Tank Program
>
PR0231331
>
COMPLIANCE INFO_2009-2014
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/4/2021 1:20:05 PM
Creation date
6/3/2020 9:44:05 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009-2014
RECORD_ID
PR0231331
PE
2351
FACILITY_ID
FA0000513
FACILITY_NAME
LODI MEMORIAL HOSPITAL
STREET_NUMBER
975
Direction
S
STREET_NAME
FAIRMONT
STREET_TYPE
AVE
City
LODI
Zip
95240
APN
03107039
CURRENT_STATUS
01
SITE_LOCATION
975 S FAIRMONT AVE
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2351_PR0231331_975 S FAIRMONT_2009-2014.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
453
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 <br /> Appendix VI 0 <br /> MONITORING SYSTEM CERTIFICATION <br /> For Use By All Jurisdictions Within the State of Cal'Ifomis <br /> Authority Cited:Chapter 6.7,Health and Safety Code;Chapter 16,Division 3,Title 23,California Code of Regulations <br /> This form must be used to document testing and servicing of monitoring equipment.A separate certification or report must be prepared for <br /> each monitoring system control panel by the technician who performs the work.A copy of this form must be provided to the tank system <br /> owner/operator.The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A. General information <br /> Facility Name: LODI MEMORIAL HOSPITAL Bldg.No.: <br /> Site Address: 9755 S FAIRMONT City: LODI Zip: <br /> Facility Contact Person: RANDY Contact Phone No.: (209)339.7657 <br /> Make/Model of Monitoring System: VEEDER ROOT TLS350 Date of Testing/Servicing: 10-09-13 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the a ro rlate'-boxes to Indicate specific ui ent ins— <br /> Tank <br /> ris servic�l: <br /> FID: EL Tank ID: <br /> g Probe. Model: MAG 1 ❑ in-Tank Gauging Probe. Model: <br /> or Vault Sensor. Model: 303 ❑ Annular Space or Vault Sensor. Model: <br /> Trench Sensor(s). Model: MAG SENSOR ❑ Piping Sump/Trench Sensor(s). Model: <br /> ® Fill Sump Sensor(s). Model: MAG SENSOR [3Fill Sump Sensor(s). Model: <br /> ❑ Mechanical Line Leak Detector. Model: ❑ Mechanical Line Leak Detector. Model; <br /> ® Electronic Line Leak Detector. Model: PLLD ❑ Electronic Line Leak Detector. Model: <br /> ❑ Tank Overfill/High-Level Sensor. Model: ❑ Tank Overfill/High-Level Sensor. Model: <br /> ❑ Other(specify equipment type and model in Section E on Page 2). ❑ Other(specify equipment type and model in Simon E on Page 2). <br /> Tank <br /> Tank ID: <br /> ❑ In-Tank Gauging Probe. Model: ❑ In-Tank Gauging Probe. Model: <br /> ❑ Annular Space or Vault Sensor. Model: ❑ Annular Space or Vault Sensor. Model: <br /> ❑ Piping Sump/Trench Sensor(,). Model: ❑ Piping Sump/Trench Sensor(s). Model: <br /> ❑ Fill Sump Sensor(s). Model: <br /> 13 Fill Sump Sensor(s). Model: <br /> ❑ Mechanical Line Leak Detector. Model: ❑ Mechanical Line Leak Detector. Model: <br /> ❑ Electronic Line Leak Detector. Model: ❑ Electronic Line Leak Detector. Model: <br /> ❑ Tank Overfill/High-Level Sensor. Model: ❑ Tank Overfill/High-Level Sensor. Model: <br /> [3 Other(specify equipment type and model in Section E on Page 2). ❑ Other(specify equipment type and model in Section E on Page 2). <br /> Dispenser ID: VENT SUMP 1 Dispenser ID: VENT SUMP 2 <br /> ® Dispenser Containment Sensor(s). Model: aAAG SENSOR ® Dispenser Containment Sensogs). Model: MAG SENSOR <br /> ❑ Shear Valve(s). ❑ Shear Valve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s). ❑ Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: FILL SUMP Dispenser ID: <br /> ® Dispenser Containment Sensogs). Model: MAG SENSOR ❑ Dispenser Containment Sensor(s). Model: <br /> ❑ Shear Valve(s). ❑ Shear Valve(s). <br /> [3 Dispenser Containment Float(s)and Chain(s). <br /> [3 Dispenser Containment Float(s)and Chain(,). <br /> Dispenser ID: Dispenser ID: <br /> ❑Dispenser Containment <br /> ❑ Dispenser Containment Sensor(s). Model: Sensor(s). Model: <br /> ❑ Shear Valve(s). ❑Shear Valve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s). ❑Dispenser Containment Float(s)and Chain(s). <br /> .t the facility contains more tanks or dispensers,copy this form. Include information for every tank and dispenser at the facility. <br /> C.Certification-1 certify that the equipment Identified In this document was Inspectediserviced in accordance with the manufacturers' <br /> guidelines.Attached to this Certification is Information(e.g.manufacturers'checklists)necessary to verify that this information is correct <br /> and a Plot Plan showing the layout of monitoring equipment For any equipment capable of generating such reports,I have also attached a <br /> copy of the report;(check aU that apply): ®System set-up ®Alarm history report <br /> Technician Name(print): FELIX RAMIREZ Signature: 'Z`�� <br /> Certification No.: 5273934-UT License No: 08-1740 <br /> Testing Company Name: AFFORDA-TEST Phone No. (209)744 0113 <br /> Testing Company Address: 416 2 STREET GALT CA 95632 Date of Testing/Servicing: 10 10-12 <br /> Monitoring System Certification <br /> Page 1 of 4 2/21/07 <br /> D. Results of TestinglServicing <br />
The URL can be used to link to this page
Your browser does not support the video tag.