My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2009-2014
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
FAIRMONT
>
975
>
2300 - Underground Storage Tank Program
>
PR0231331
>
COMPLIANCE INFO_2009-2014
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/4/2021 1:20:05 PM
Creation date
6/3/2020 9:44:05 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009-2014
RECORD_ID
PR0231331
PE
2351
FACILITY_ID
FA0000513
FACILITY_NAME
LODI MEMORIAL HOSPITAL
STREET_NUMBER
975
Direction
S
STREET_NAME
FAIRMONT
STREET_TYPE
AVE
City
LODI
Zip
95240
APN
03107039
CURRENT_STATUS
01
SITE_LOCATION
975 S FAIRMONT AVE
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2351_PR0231331_975 S FAIRMONT_2009-2014.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
453
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Monitdring System Certification Form: endum for Vacuum/Pressure Interstitial Mrs <br /> I. Results of Vacuum/Pressure Monitoring Equipment Testing <br /> This page should be used to document testing and servicing of vacuum and pressure interstitial sensors. A copy of <br /> this form must be included with the Monitoring System Certification Form, which must be provided to the tank <br /> system owner/operator. The owner/operator must submit a copy of the Monitoring System Certification Form to the <br /> local agency regulating UST systems within 30 days of test date. <br /> Manufacturer:VEEDER ROOT Model:TLS350 System Type: ❑Pressure; ®Vacuum <br /> Elm 1 <br /> r <br /> sor ID <br /> Component(s)Monitored by this Sensor: FUEL OIL RETURN LINE <br /> S1 ❑ Fail <br /> Sensor Functionality Test Result: ®Pass; El Interstitial Communication Test Result: ®Pass; <br /> Component(s)Monitored by this Sensor: FUEL OIL SUPPLY OIL LINE <br /> S2 <br /> Sensor Functionality Test Result: ®Pass; El Fail Interstitial Communication Test Result: ®Pass; Fail <br /> Component(s)Monitored by this Sensor: VENT LINE <br /> S3 ❑ <br /> Sensor Functionality Test Result: ®Pass; ❑ Fail Interstitial Communication Test Result: ®Pass•, Fail <br /> Component(s)Monitored by this Sensor: REMOTE FILL LINE <br /> S4 <br /> Sensor Functionality Test Result: ®Pass; E] Fail Interstitial Communication Test Result:®Pass; Fail <br /> Component(s)Monitored by this Sensor: <br /> Sensor Functionality Test Result: ❑Pass; ❑ Fail Interstitial Communication Test Result: ❑Pass; ❑ Fail <br /> Component(s)Monitored by this Sensor: <br /> Sensor Functionality Test Result: ❑Pass; ❑ Fail Interstitial Communication Test Result: ❑Pass; ❑ Fail <br /> Component(s)Monitored by this Sensor: <br /> Sensor Functionality Test Result: ❑Pass; ❑ Fail Interstitial Communication Test Result: El Pass; ❑ Fail <br /> Component(s)Monitored by this Sensor: <br /> Sensor Functionality Test Result: ❑Pass; ❑ Fail Interstitial Communication Test Result: ❑Pass; ❑ Fail <br /> Component(s)Monitored by this Sensor: <br /> Sensor Functionality Test Result: ❑Pass; ❑ Fail Interstitial Communication Test Result: ❑Pass; ❑ Fail <br /> Component(s)Monitored by this Sensor: <br /> Sensor Functionality Test Result: ❑Pass; ❑ Fail Interstitial Communication Test Result: ❑Pass; ❑ Fail <br /> How was interstitial communication verified? <br /> ❑ Leak Introduced at Far End of Interstitial Space;' ❑ Gauge; ® Visual Inspection; ❑ Other(Describe in Sec.J, below) <br /> Was vacuum/pressure restored to operating levels in all interstitial spaces? ®Yes ❑No(If no, describe in Sec.J, below) <br /> J. Comments: Lodi Memorial Hospital 10-9-13 <br /> Page 4 of 4 <br /> ' If the sensor successfully detects a simulated vacuum/pressure leak introduced in the interstitial space at the furthest point from the <br /> sensor,vacuum/pressure has been demonstrated to be communicating throughout the interstice. <br /> UN-036A-1/1 www.unidocs.org Rev.01/26/06 <br />
The URL can be used to link to this page
Your browser does not support the video tag.