My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2009-2014
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
FAIRMONT
>
975
>
2300 - Underground Storage Tank Program
>
PR0231331
>
COMPLIANCE INFO_2009-2014
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/4/2021 1:20:05 PM
Creation date
6/3/2020 9:44:05 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009-2014
RECORD_ID
PR0231331
PE
2351
FACILITY_ID
FA0000513
FACILITY_NAME
LODI MEMORIAL HOSPITAL
STREET_NUMBER
975
Direction
S
STREET_NAME
FAIRMONT
STREET_TYPE
AVE
City
LODI
Zip
95240
APN
03107039
CURRENT_STATUS
01
SITE_LOCATION
975 S FAIRMONT AVE
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2351_PR0231331_975 S FAIRMONT_2009-2014.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
453
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
IN-TANK SETUP- - - - - - PRESSURE LINE-LEAK SETUP *OUTPUT-RELAY SETUP <br /> - - - - - - 0 - - - - - - - - - - - <br /> T I :DIESEL FUEL Q 1 :DIESEL SUPPLY LINE R i :OVERFILL ALARM <br /> PRODUCT CODE I TYPE' <br /> THERMAL COEFF : .000450 DEFINED STANDARD <br /> TYP:USER <br /> TANK DIAMETER 119.63 1ST LINE LEN: 60 FEET NORMALLY OPEN <br /> TANK PROFILE 4 PTS 2ND LINE LEN: 0 FEET <br /> FULL VOL 19951 M: 150 IN <br /> . . <br /> 89.7 INCH VOL 16204 IST LINE DIAIN-TANK ALARMS <br /> 59.8 INCH VOL 9976 IST BULK MOD: 8600 PSI ALL:oVERFILL ALARM <br /> 29.9 INCH VOL 3790 THERMAL COEFF :0.000450 ALL:HIGH PRODUCT ALARM <br /> SHUTDOWN RATE: NONE ALL:MAX PRODUCT ALARM <br /> LOW PRESSURE SHUTOFF:NO <br /> FLOAT SIZE: 4.0 IN. LOW PRESSURE : 10 PSI R 2:BUILDING MGT SYSTEM <br /> T I :DIESEL FUEL TYPE: <br /> WATER WARNING 2.0 STANDARD <br /> DISPENSE MODE: <br /> HIGH WATER LIMIT: 3.0 STANDARD NORMALLY OPEN <br /> MAX OR LABEL VOL: 19951 SENSOR: NON-VENTED <br /> PRESSURE OFFSET: O.OPSI IfIs <br /> OVERFILL LIMIT 90% III-TANK ALAR <br /> 17956 ALL:HIGH WATER ALARM <br /> HIGH PRODUCT 95% MECHANICAL BLENDER: NO ALL:OVERFILL ALARM <br /> 18953 ALL:LOW PRODUCT ALARM <br /> DELIVERY LIMIT 15% ALL:SUDDEN LOSS ALARM <br /> 2992 ALL:HIGH PRODUCT ALARM <br /> LINE LEAK LOCKOUT SETUP ALL:INVALID FUEL LEVEL <br /> LOW PRODUCT 2420 - - - - - - - - - - - - ALL:PROBE OUT <br /> LEAK ALARM LIMIT: 99' LOCKOUT SCHEDULE ALL:HIGH WATER WARNING <br /> SUDDEN LOSS LIMIT: 1000 DAILY ALL:DELIVERY NEEDED <br /> TANK TILT 0.00 START TIME: DISABLED ALL:MAX PRODUCT ALARM <br /> STOP TIME DISABLED <br /> PROBE OFFSET 0.00 LIQUID SENSOR ALMS <br /> ALL:FUEL ALARM <br /> SIPHON MANIFOLDED TANKS ALL:SENSOR OUT ALARM <br /> T#: NONE ALL:SHORT ALARM <br /> LINE MANIFOLDED TANKS ALL:WATER ALARM <br /> T#: NONE ALL:WATER OUT ALARM <br /> ALL:HIGH LIQUID ALARM <br /> ALL:LOW LIQUID ALARM <br /> LEAK MIN PERIODIC: 0% ALL:LIQUID WARNING <br /> 0 PRESSURE LINE LEAK <br /> LEAK MIN ANNUAL 0% ALL:GROSS LINE FAIL <br /> 0 LIQUID SENSOR SETUP ALL:PLLD OPEN ALARM <br /> - - - - - - - - - - - - ALL:PLLD SHUTDOWN ALARM <br /> PERIODIC TEST TYPE L I :VENT TRNS SUMP BRINE ALL:FUEL OUT <br /> STANDARD TRI-STATE (SINGLE FLOAT) SMARTSENSOR ALARMS <br /> CATEGORY : PIPING SUMP ALL:COMMUNICATION ALARM <br /> ANNUAL TEST FAIL ALL:SENSOR FAULT ALARM <br /> ALARM DISABLED ALL:FUEL WARNING <br /> L 2:LINE TRNS SUMP BRINE <br /> PERIODIC TEST FAIL TRI-STATE (SINGLE FLOAT) ALL:FUEL ALARM <br /> ALARM DISABLED CATEGORY : PIPING SUMP ALL:WATER WARNING <br /> ALL:WATER ALARM <br /> GROSS TEST FAIL ALL:HIGH LIQUID WARNING <br /> L 3:DIESELTANK ANNULAR <br /> ALARM DISABLED ALL:HIGH LIQUID ALARM <br /> DUAL POINT HYDROSTATIC ALL:LOW LIQUID WARNING <br /> ANN TEST AVERAGING: OFF CATEGORY : ANNULAR SPACE ALL:LOW LIQUID ALARM <br /> PER TEST AVERAGING: OFF ALL,.TEMPERATURE WARNING <br /> ALL'.RELAY ACTIVE <br /> TANK TEST NOTIFY: OFF ALL:INSTALL ALARM <br /> L 4:RMTE FILL SUMP BRINE ALL:SENSOR FAULT WARN <br /> TNK TST SIPHON BREAK OFF TRI-STATE (SINGLE FLOAT) ALL:VACUUM WARNING <br /> CATEGORY : PIPING SUMP ALL:NO VACUUM ALARM <br /> DELIVERY DELAY 5 MIN <br /> PUMP THRESHOLD 10-00% L 5:TANK FILL SUMP BRINE <br /> TRI-STATE (SINGLE FLOAT) <br /> CATEGORY : PIPING SUMP <br /> LEAK TEST METHOD <br /> - - - - - - - - - - - - <br /> TEST ON DATE : ALL TANK L 6:DIESEL TURB SUMP BRN <br /> JUL 23, 2010 TRI-STATE (SINGLE FLOAT) <br /> START TIME : DISABLED CATEGORY : STP SUMP <br /> TEST RATE :0.20 GAL/HR <br /> DURATION 2 HOURS PLLD LINE DISABLE_SETUP_ <br /> TST EARLY STOP:DISABLED <br /> Q I : IESEL LINE <br /> LEAK TEST REPORT FORMAT - NoDALARM ASSIGSUPPLYNMENTS <br /> NORMAL <br />
The URL can be used to link to this page
Your browser does not support the video tag.