Laserfiche WebLink
RECEIVED <br /> Monitoring System Certification For ddendum for Vacuum/Pressure Interstitia0k sora <br /> ' <br /> . Results of Vacuum/Pressure Monitoring Equipment Testing NOVN3 0 207 <br /> This page should be used to document testing and servicing of vacuum and pres js. f <br /> this form must be included with the Monitoring System Certification Form, which mus t e tank <br /> system owner/operator. The owner/operator must submit a copy of the Monitoring System Certs ication orm to the <br /> local agency regulating UST systems within 30 days of test date. <br /> SITE: LODI MEMORIAL HOSPTIAL 975 S FAIRMONT LODI CA 95240 <br /> Manufacturer:VEEDER ROOT Model: TLS350 System Type: ❑ Pressure; ®Vacuum <br /> Sensor ID <br /> Component(s)Monitored by this Sensor: FUEL OIL RETURN LINE <br /> S1 <br /> Sensor Functionality Test Result: ®Pass; ❑ Fail Interstitial Communication Test Result: ®Pass; ❑ Fail <br /> S2 Component(s)Monitored by this Sensor: FUEL OIL SUPPLY OIL LINE <br /> Sensor Functionality Test Result: ®Pass; ❑ Fail Interstitial Communication Test Result: ®Pass; ❑ Fail <br /> S3 Component(s)Monitored by this Sensor: VENT LINE <br /> Sensor Functionality Test Result: ®Pass; ❑ Fail Interstitial Communication Test Result: ®Pass; ❑ Fail <br /> S4 Component(s)Monitored by this Sensor: REMOTE FILL LINE <br /> Sensor Functionality Test Result: ® Pass; ❑ Fail Interstitial Communication Test Result: ®Pass; ❑ Fail <br /> Component(s)Monitored by this Sensor: <br /> Sensor Functionality Test Result: ❑ Pass; ❑ Fail Interstitial Communication Test Result: ❑Pass; ❑ Fail <br /> Component(s)Monitored by this Sensor: <br /> Sensor Functionality Test Result: ❑Pass; ❑ Fail Interstitial Communication Test Result: ❑Pass; ❑ Fail <br /> Component(s)Monitored by this Sensor: <br /> Sensor Functionality Test Result: ❑Pass; ❑ Fail Interstitial Communication Test Result: ❑Pass; ❑ Fail <br /> Component(s)Monitored by this Sensor: <br /> Sensor Functionality Test Result: ❑Pass; ❑ Fail Interstitial Communication Test Result: ❑Pass; ❑ Fail <br /> Component(s)Monitored by this Sensor: <br /> Sensor Functionality Test Result: ❑Pass; ❑ Fail Interstitial Communication Test Result: ❑Pass; ❑ Fail <br /> Component(s)Monitored by this Sensor: <br /> Sensor Functionality Test Result: ❑Pass; ❑ Fail Interstitial Communication Test Result: ❑Pass; ❑ Fail <br /> How was interstitial communication verified? <br /> ❑ Leak Introduced at Far End of Interstitial Space;' ® Gauge; ® Visual Inspection; ❑ Other(Describe in Sec.J, below) <br /> Was vacuum/pressure restored to operating levels in all interstitial spaces? ®Yes ❑No(If no, describe in Sec.J, below) <br /> J. Comments: <br /> Page 4 of 4 <br /> ' If the sensor successfully detects a simulated vacuum/pressure leak introduced in the interstitial space at the furthest point from the <br /> sensor,vacuum/pressure has been demonstrated to be communicating throughout the interstice. <br /> UN-036A-1/1 www.unidocs.org Rev.01/26/06 <br />